Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)
Rated Flow Range: 60 to 6000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: Made to Order
Rated Flow Range: 60 to 6000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 1 1/2, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: Made to Order
The zero cut-off range is 0.0 to 10.0%F.S., and can be set in 1.0%F.S. increments. < Operation > Display [F14] by pressing UP or DOWN button in function selection mode. Press the SET button. Move on to select zero cut-off setting (flow rate).
[F14] Zero cut-off setting completed : When setting the flow value and hysteresis within zero cut-off settable range, the on-off point varies depending on the settable range. However, please note that the setting and hysteresis of the switch output will not be changed.
] Zero-cut 0 1.0F.S.0.010.0F.S. <> UP DOWN [F14] SET Zero-cut Zero-cut UP DOWN Zero-cut Zero-cut 1%F.S.cut 2%F.S.cut 10%F.S.cut ISE70(1 MPa )[MPa] 1 MPa P_1=0.015[MPa]H_1=0.01[MPa]Zero-cut1.0 [MPa] 0.0(Zero-cut) 1.0(1%F.S.cut) Zero-cut (1.0%) Zero-cut SW SET [F14] Zero-cut -45No.PS-OMV0003CN-G [F80] 30 <> UPDOWN[F80] SET UP DOWN SET [F80] 30 () [ECo] (ON) ON OFF -46No.PS-OMV0003CN-G
] Zero-cut 0 0.010.0F.S.1.0F.S. <> UP DOWN [F14] SET Zero-cut Zero-cut UP DOWN Zero-cut Zero-cut 1%F.S.cut 2%F.S.cut 10%F.S.cut ISE70G(1 MPa )[MPa] 1 MPa P_1=0.015[MPa]H_1=0.01[MPa]Zero-cut1.0 [MPa] 0.0(Zero-cut) 1.0(1%F.S.cut) Zero-cut (1.0%) Zero-cut SW SET [F14] Zero-cut -48No.PS-OMV0008CN-E [F80] 30 <> UPDOWN[F80] SET UP DOWN SET [F80] 30 () [ECo] (ON) ON OFF -49No.PS-OMV0008CN-E