Digital Flow Switch Modular Type, SENSOR, DIGITAL AIR FLOW, O24, 0.49000 lb
Display Digital Flow Switch Modular Type, DIGITAL FLOW SWITCH, MODULAR, P65, 0.49000 lb
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: Q (Lead wire with M12-M12 connector, 3 m)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: Q (Lead wire with M12-M12 connector, 3 m)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 20 to 2000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
The -L models include IO-Link and digital outputs with optional analog outputs. Rated flow range: PF3A701H: 10 TO 1000 lpm; PF3A702H: 20 to 2000 lpm; Large 2 screen, 3 color display to show both instantaneous and cumulative flow or set value at the same time; Can be converted to threaded model using modular connectors and piping adapters ; Accuracy: +/-3.0% F.S.