Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Yes), Flow Direction: R (Right to Left)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: Q (Lead wire with M12-M12 connector, 3 m)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: Q (Lead wire with M12-M12 connector, 3 m)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None]
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series]
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series]
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -, Flow Direction: -