Maximum measured Maximum measured Minimum measured Minimum measured Part no. flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] PF2A510--1 PF2A550--1 PF2A511--1 PF2A521--1 PF2A551--1 PF2A510--2 PF2A550--2 PF2A511--2 PF2A521--2 PF2A551--2 10 50 100 200 500 10 50 100 200 500 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1.1 5.4 11 21 54 10.7 53.5 107 214
Maximum measured Maximum measured Minimum measured Minimum measured Part no. flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] flow rate value [l/min] PF2A510--1 PF2A550--1 PF2A511--1 PF2A521--1 PF2A551--1 PF2A510--2 PF2A550--2 PF2A511--2 PF2A521--2 PF2A551--2 10 50 100 200 500 10 50 100 200 500 1.1 5.4 11 21 54 10.7 53.5 107 214 535 1.1 5.4 11 21 54 10.7 53.5 107 214
Pin description 2-Port size 44.5 40 30 1 DC(+) 50 2 OUT2 3 DC() 4 OUT1 (42.2) 73 Flow direction 6 Series PF2A Dimensions: Remote Type Sensor Unit for Air PF2A510, 550 Internal circuits and wiring examples 98 to are the terminal numbers.
counter M/C Flow control for each branch line For Air P.2 50l/min 10l/min 500l/min 200l/min 100l/min 12000l/min 6000l/min 3000l/min Flow rate measurement range l/min Integrated display type Remote type Output specifications Port size (Rc, NPT, G) 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse output Display unit Sensor unit PF2A710 750 711 721 751 703H 706H 712H PF2A510
. -19No.PF-OMG0008-F Initialize mode Default settings PF2A3 series Item Default settings Page PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Selection of the connected sensor Page 21 PF2A31 series [11L] 10 to 100 L/min type (PF2A511) Selection of display mode [d_1] Display instantaneous flow Page 22 Unit selection function [U_1] L/min Selection of output mode (OUT1) [o10] Instantaneous
. -20No.PF-OMH0003-F Initialize mode Default settings PF2A20 series Item Default settings Page Selection of the connected sensor [10L] 1 to 10 L/min type (PF2A510) Page 22 Selection of display mode [d_1] Display instantaneous flow Page 23 Unit selection function [U_1] L/min Selection of output mode [o10] Instantaneous output mode Selection of switch operation [1_n] Reverse output Page 24
Hysteresis mode 2 Panel Item Default settings Model button (UP) Panel mount adapter Item Default setting ( ) PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Indicator LED (OUT1) Set point 1 Set point 2 Hysteresis 1 Hysteresis 1 50% of max. rated flow [n_1] Input of the Set point 1 (OUT1) PF2A31 series [11L] 10 to 100 L/min type (PF2A511) button (SET) ON 50% of max. rated flow [n_2] Input
FLOW Hysteresis 1 Hysteresis 1 SET Set point 1 Set point 2 button (UP) button (DOWN) button (SET) ON Item Default settings Model Item Default setting Instantaneous flow PF2A2 series [10L] 1 to 10 L/min type (PF2A510) Connecting the wiring Attaching the sensor connector to the sensor wire Strip the sensor wire as shown. Do not cut the insulator.
Can be changed to window comparator mode using push-buttons. 908 2-Color Display Digital Flow Switch Series PFM7 Piping Specifications / Mass Part no. 01 02 N01 N02 F01 C4 F02 4 (5/32") one-touch fitting C6 C6 8 (5/16") one-touch fitting N7 1/4" one-touch fitting 6 one-touch fitting Rc 1/4 NPT 1/8 NPT 1/4 Rc 1/8 Port size G1/8 G1/4 Straight Without orifice: 95 g Bottom Without orifice: 105
How to Order 01 01 3 0 VM8 Actuator type Port size Basic 00 Rc 01 1 8 Roller lever 01 1 8 NPT N01 Adjustable roller lever 13 G F01 1 8 Adjustable rod lever 14 Number of ports 3 3 port Application Movement is changeable. Roller can be mounted to inside of lever.
How to Order 01 01 3 0 VM8 Actuator type Port size Basic 00 Rc 01 1 8 Roller lever 01 1 8 NPT N01 Adjustable roller lever 13 G F01 1 8 Adjustable rod lever 14 Number of ports 3 3 port Application Movement is changeable. Roller can be mounted to inside of lever.
How to Order 01 01 3 0 VM8 Actuator type Port size Basic 00 01 Rc 1 8 Roller lever 01 NPT 1 8 G 1 8 N01 F01 Adjustable roller lever 13 Adjustable rod lever 14 Number of ports 3 3 port Application Movement is changeable. Roller can be mounted to inside of lever.
50 -8No.PF-OMJ0005CN-I * 3 (20 ) LED * OUT * 23% -9No.PF-OMJ0005CN-I 7 PFM (12) 2 (11) 10 0.210(5)L/min 1 25 0.525(12.5)L/min (11) 50 150(25)L/min 11 2100(50)L/min 1( )CO2 A 2 2 S () N 3 M SI4 3 (SI) 4L/min,L A NPN(2) B PNP(2) C NPN(1)+(15V) D NPN(1)+(420mA) E PNP(1)+(15V) F PNP(1)+(420mA) G NPN(1)+5 H PNP(1)+5 5 L 6INOUT () 10 25 50 11 01 Rc1/8 02 Rc1/4 N01 NPT1/8 N02 NPT1/4 F01
G ARP20P-320AS-01 Plug assembly Rc ARP20P-320AS-N01 NPT ARP20P-320AS-F01 G AR20P-370AS-01 Plug Rc AR20P-370AS-N01 PBT RESIN NPT AR20P-370AS-01 G AR23KP-020AS Check valve assembly Check valve plug assembly AR20KP-090AS Note 1 Bracket and Set nut assembly.
Port size Type Symbol Cylinder side In the side of solenoid valve M5 01 02 03 04 F01 F02 F03 F04 U10/32 N01 N02 N03 N04 Elbow 2 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 G 1/8 G 1/4 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Control 0 1 Meter-out Meter-in 15-9-89 16 Construction AS2200
(mm) 1in=25.4mm L4 D3 H (width across flats) T2 A L2 D1 L3 D2 T1 L1 Dimensions A Model T2 H D1 T1 D2 D3 L3 L1 L4 L2 AS12 0-M5-T M5 x 0.8 8 9 M5 x 0.8 9 4.5 10 31 10.3 0.7 28.4 AS12 0-U10/32-T 10-32UNF 10-32UNF AS22 0-01-ST Rc 1/8 12 14.3 R 1/8 AS22 0-F01-ST PF 1/8 14.6 7 18 35.6 14.1 1.5 32 AS22 0-N01-ST NPT 1/8 12.7 NPT 1/8 AS22 0-02-ST Rc 1/4 17 18 R 1/4 AS22 0-F02-ST PF 1/4 19.5 7 27.2
Body size 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Port size Type Symbol Cylinder side In the side of solenoid valve M5 01 02 03 04 F01 F02 F03 F04 U10/32 N01 N02 N03 N04 Elbow 2 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 G 1/8 G 1/4 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT
Body size 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Port size Type Symbol Cylinder side In the side of solenoid valve M5 01 02 03 04 F01 F02 F03 F04 U10/32 N01 N02 N03 N04 Elbow 2 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 G 1/8 G 1/4 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT
Port size Symbol Cylinder side In the side of solenoid valve M5 01 Elbow M5 x 0.8 R 1/8 M5 x 0.8 Rc 1/8 Rc 1/4 Note 1) 02 R 1/4 Rc 3/8 Note 2) 03 04 F01 Rc 3/8 Rc 1/2 G 1/8 G 1/4 Note 1) R 3/8 R 1/2 R 1/8 Caution Control F02 R 1/4 Meter-out Meter-in Be sure to read before handling.
Body Output for PF2A3 + Analogue (1 to 5 V) type: PF2A5 -1Output for PF2W3 + Analogue (1 to 5 V) type: PF2W5 -1Safety Instructions Model Width across flats of attachment Piping port (IN side) Bracket Sensor Monitor PF23 PF2A510 : This drawing is the model of PF2W504/520. 24 mm These safety instructions are intended to prevent hazardous situations and/or equipment damage.