03 04 1/8 1/4 3/8 1/2 PF2A510/550 PF2A511/521 PF2A551 Specifications PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 Model Measured fluid Air, Nitrogen Detection type Heater type 20 to 200l/min 50 to 500l/min 1 to 10l/min 5 to 50l/min Flow rate measuring range 10 to 100l/min Operating pressure range 50kPa to 0.5MPa 50kPa to 0.75MPa Proof pressure 1.0MPa 0 to 50C Operating fluid temperature 5%

03 04 1/8 1/4 3/8 1/2 PF2A510/550 PF2A511/521 PF2A551 Specifications PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 Model Measured fluid Air, Nitrogen Detection type Heater type 20 to 200 l/min 50 to 500 l/min 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min Flow rate measuring range 50 kPa to 0.5 MPa 50 kPa to 0.75 MPa Operating pressure range Proof pressure 1.0 MPa Operating fluid temperature 0

03 04 1/8 1/4 3/8 1/2 PF2A510/550 PF2A511/521 PF2A551 Specifications PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 Model Measured fluid Air, Nitrogen Detection type Heater type 20 to 200l/min 50 to 500l/min 1 to 10l/min 5 to 50l/min Flow rate measuring range 10 to 100l/min Operating pressure range 50kPa to 0.5MPa 50kPa to 0.75MPa Proof pressure 1.0MPa 0 to 50C Operating fluid temperature 5%

Port size Port size Applicable model Flow rate (l/min) Symbol Lead wire (Refer to page 35.) 100 200 500 50 10 01 02 03 04 Nil N M12 3 m lead wire with connector Without lead wire 1/8 1/4 3/8 1/2 PF2A510/550 PF2A511/521 PF2A551 Output specification Symbol Nil 1 2 Applicable display unit (monitor) model Specification Series PF2A300 Series PF2A200/300 Series PF2A300 Output for display

. -19No.PF-OMG0008-F Initialize mode Default settings PF2A3 series Item Default settings Page PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Selection of the connected sensor Page 21 PF2A31 series [11L] 10 to 100 L/min type (PF2A511) Selection of display mode [d_1] Display instantaneous flow Page 22 Unit selection function [U_1] L/min Selection of output mode (OUT1) [o10] Instantaneous

. -20No.PF-OMH0003-F Initialize mode Default settings PF2A20 series Item Default settings Page Selection of the connected sensor [10L] 1 to 10 L/min type (PF2A510) Page 22 Selection of display mode [d_1] Display instantaneous flow Page 23 Unit selection function [U_1] L/min Selection of output mode [o10] Instantaneous output mode Selection of switch operation [1_n] Reverse output Page 24

Hysteresis mode 2 Panel Item Default settings Model button (UP) Panel mount adapter Item Default setting ( ) PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Indicator LED (OUT1) Set point 1 Set point 2 Hysteresis 1 Hysteresis 1 50% of max. rated flow [n_1] Input of the Set point 1 (OUT1) PF2A31 series [11L] 10 to 100 L/min type (PF2A511) button (SET) ON 50% of max. rated flow [n_2] Input

FLOW Hysteresis 1 Hysteresis 1 SET Set point 1 Set point 2 button (UP) button (DOWN) button (SET) ON Item Default settings Model Item Default setting Instantaneous flow PF2A2 series [10L] 1 to 10 L/min type (PF2A510) Connecting the wiring Attaching the sensor connector to the sensor wire Strip the sensor wire as shown. Do not cut the insulator.

Body Output for PF2A3 + Analogue (1 to 5 V) type: PF2A5 -1Output for PF2W3 + Analogue (1 to 5 V) type: PF2W5 -1Safety Instructions Model Width across flats of attachment Piping port (IN side) Bracket Sensor Monitor PF23 PF2A510 : This drawing is the model of PF2W504/520. 24 mm These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)

Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 0 (NPN Open Collector 2 Outputs)

Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 1 (PNP Open Collector 2 Outputs)

Flow Range: 0 (PF2A510: 1-10l/min, PF2A550: 5-50l/min), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)

Sensor 1 L/min 5 L/min 10 L/min 20 L/min 50 L/min 100 L/min 200 L/min 500 L/min Flow rate range 1 L/min 10 L/min PF2A510 0.5 L/min 10.5 L/min 5 L/min 50 L/min PF2A550 52.5 L/min 2.5 L/min 10 L/min 100 L/min PF2A511 105 L/min 5 L/min 20 L/min 200 L/min 210 L/min 10 L/min PF2A521 50 L/min 500 L/min 525 L/min 25 L/min PF2A551 Sensor Flow rate range Static Electricity

Flow Range: PF2A510: 1-10l/min, PF2A550: 5-50l/min, Output Specification: NPN Open Collector 2 Outputs, Unit: S1 Fixed Unit

Flow Range: PF2A510: 1-10l/min, PF2A550: 5-50l/min, Output Specification: NPN Open Collector 2 Outputs, Unit: -

Flow Range: PF2A510: 1-10l/min, PF2A550: 5-50l/min, Output Specification: PNP Open Collector 2 Outputs, Unit: -

Flow Range: PF2A510: 1-10l/min, PF2A550: 5-50l/min, Output Specification: PNP Open Collector 2 Outputs, Unit: S1 Fixed Unit

Flow Range: 10 (1~10l/min), Thread: F (G thread), Port Size: 02 (Port Size 1/4), Wiring Specification: N (w/o Lead Wire)

Flow Range: 10 (1~10l/min), Thread: N (NPT Thread), Port Size: 01 (Port Size 1/8), Wiring Specification: N (w/o Lead Wire)