Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0300 (3 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 0.5M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0300 (3 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F7PL--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0300 (3 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0300 (3 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M

Magnet: Built-in, Bore Size: 3/8 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 3 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 5/8 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 3 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Small Holding Force, Stroke: 3 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 3 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 0300 (3 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 6 (1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0300 (3 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M

3m 100V AC 5-20mA max 24V ACDC 50mA Reed Connector D-A80CL PLC 0 None 3m 48V ACDC 40mA 100V ACDC 20mA Note: Pre-wired Switches with 3/4 Pin Connectors available H O W T O O R D E R S T O P P E R C Y L I N D E R S E R I E S RS(D)Q ACCESSORIES S T O P P E R C Y L I N D E R S E R I E S RSQ XC18 RS D Q D Auto Switches Reed Type With Lamp D-A79L Without Lamp D-A80L Solid State Type (NPN) D-F79L

Friction Coupling ACCESSORIES FRICTION COUPLING ACCESSORIES AUTO SWITCHES Zero Max Size ETP-K-12-C 32 MODEL ETP-K-14-C 40 Part no Part no Grommet Type Connector Type TYPE LOAD VOLTAGE LOAD CURRENT POWER SOURCE INTERNAL VOLTAGE DROP INDICATOR LAMP D-A73L D-A73CL REED 24VDC 100VAC 5~40mA 5~20mA MAX 2.4V ON:RED LED D-A80L D-A80CL REED 24VDC/AC OR LESS 100VDC/AC MAX 50mA MAX 20mA 0 NONE D-F79L

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1200 (12 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2000 (20 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 2 Inch, Adjuster: Adjuster Bolt, Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 2 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 3 Inch, Adjuster: Adjuster Bolt, Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 3 Inch, Adjuster: Cap Type Shock Absorber (2 pcs.), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 4 Inch, Adjuster: Adjuster Bolt, Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -

Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 4 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M, Number: -