SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S15L-3000"

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 3000 (30 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73L--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 3M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 3000 (30 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 3000 (30 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F79L--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 3000 (30 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 3000 (30 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, Horizontal, 0.5M

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW, 3.41715 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, GC, 15MM NCY2S OTHERS (COMBO)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, HIGH SPD, ACTUATOR, NCY2S GUIDED CYLINDER, GC, 15MM NCY2S OTHERS (COMBO), .00000 lb

m (kg) 1000 a = 1000 to 3000 L2 500 Mer m 5 10 0 Transfer load m (kg) a 1000 Mey a = 1000 to 3000 500 m L3 5 10 0 Transfer load m (kg) Refer to page 304 for deflection data. 268 5 Phase Stepper Motor/Without Motor Brake Series LXS Dimensions/LXSH5BD Scale: 25% F G x I +0.030 0 depth 5 +0.030 0 depth 5 5H9 D-5.1 through Refer to Cross section C-C, bottom view.

0 2 4 6 8 10 Transfer load m (kg) 600 L2 400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 2000 L3 (mm) L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for deflection data. 2 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area

Can be connected with the ZK2 series vacuum unit p. 7 JSY3000 JSY3000 Ejector System JSY1000 JSY5000 Vacuum Unit ZK2 JSY1000/3000/5000 Series CAT.ES11-110B a Plug-in Compact 5-Port Solenoid Valve JSY1000/3000/5000 Series Series Map JSY1000 JSY3000 JSY5000 Valve width 39% reduction 36% reduction 35% reduction 6.4 mm b 10 mm 10 mm b 15.5 mm 15 mm b 24.6 mm 29% reduction 32% reduction 59% reduction

0 2 4 6 8 10 Transfer load m (kg) 600 L2 400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 2000 L3 (mm) L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for deflection data. 2 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area

Note) VQZ2000/3000 DIN terminal rubber seal only (except external pilot). For details on IP65 enclosure, refer to page 966.