Search Results "NCDMC125-1000-M9P"

or less 1000 or less 1600 or less -XC27 140 1000 or less 1000 or less 1600 or less Rod side trunnion mounted on the front of the rod cover RHC -XC30 160 1200 or less 1200 or less 1600 or less Made of stainless steel (With hard chrome plated piston rod) -XC68 RZQ Accessory -XC86 With rod end bracket Basic Foot Rod flange Head flange Single clevis Double clevis Center trunnion For the specifications

40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 1000 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 1000 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500

Graph (3) 20 x 9.8 x (0.07 + 0.05) x 10/1000 = 0.24 20 x 9.8 x (m1 + m2) x H/1000 0.24 Nm < Effective torque OK < Effective torque (Nm) Find the moment of inertia, "IR" for the load + attachments (2 pcs.) 7 IR = K x (a2 + b2 + 12h2) x (m1 + m2)/(12 x 106) IR = 2 x (202 + 302 + 12 x 102) x (0.07 + 0.05)/(12 x 106) = 0.05 kgm2 (K = 2: Safety factor) Kinetic energy 8 Confirm that the kinetic

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

) (900) (1000) (900) (1000) (1000) MY1C20 MY1C20 MY1C20 MY1C20 MY1C16 MY1C16 MY1C16 MY1C16 MY1C16 MY1C16 (900) (900) 20 10 0 1000 2000 3000 5000 4000 Support spacing (l ) (mm) 8-11-65 63 Series MY1C Construction: 16 to 63 $1 #3 !

Bore size (mm) Standard stroke (mm) Note 1) Maximum manufacturable stroke (mm) CS1 20 Symbol Specifications CS2 25, 50, 75, 100, 125, 150, 200, 250, 300 1000 25 -X446 PTFE grease 32 Made to Order (For details, refer to pages 1703 to 1896.) 40 Note 1) Intermediate strokes not listed above are produced upon receipt of order.

800 Up to 800 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Up to 1000 37 44 50 56 66 8-25-11 11 Series MGZ With Mounting Bracket Transaxial foot style: (L) 4-LD through LT LH LY X/2 ZZ + Stroke LS + Stroke X X Y LZ LX (mm) Stroke range Bore size (mm) LS ZZ LD Y X LH LT LX LY LZ Up to 800 Up to 800 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Up to 1000 20 25 32 40 50 63 80 86 107 120 138 148

mm/s 50 to 700 mm/s st + 1.4 0 Stroke length tolerance Up to 1000 mm, Up to 1200 mm Up to 1000 mm Symbol st + 1.4 0 st + 1.8 0 st + 1.8 0 Up to 1500 mm Rubber bumper Cushion Rubber bumper, Air cushion Mounting ** Basic, Axial foot, Rod flange, Head flange, Rod trunnion, Head trunnion, Clevis * 0.05 MPa except locking parts. ** Rod/Head trunnion types are not available for 80 and 100.

Cylinder speed 1000 mm/sec. PLC response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v v Grommet Solid

Note 4) The stroke range with rod boot is up to 1000 mm. Please consult with SMC when exceeding 1000 mm strokes.

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

] Horizontal/Bottom mounting 1000 1000 800 800 L2 L2 [mm] L2 [mm] 600 600 m Y 400 400 200 200 0 0 2 4 6 8 10 0 0 5 10 15 20 Work load [kg] Work load [kg] 2000 2000 1500 1500 m L3 [mm] L3 [mm] 1000 1000 L3 Z 500 500 0 0 2 4 6 8 10 0 0 5 10 15 20 Work load [kg] Work load [kg] 2000 2000 1500 1500 L4 L4 [mm] L4 [mm] 1000 1000 X m 500 500 0 0 2 4 6 8 10 0 0 5 10 15 20 Work load [kg] Work load

1000 1000 LC3F2 800 800 1500 1500 L5 [mm] L5 [mm] L5 [mm] L5 [mm] Bottom m Me 600 600 1000 1000 Y L5 400 400 500 500 200 200 0 0 0 0 0 10 5 15 20 0 10 5 15 20 30 25 0 10 40 50 20 30 0 10 40 50 20 30 60 70 80 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 2000 2000 1000 1000 800 800 1500 1500 L6 [mm] L6 [mm] L6 [mm] L6 [mm] L6 600 600 m Me 1000 1000 Z 400 400 500 500 200 200

Cylinder speed 1000 mm/sec. Sequencer response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using.

Magnet: D (Built-in), Mounting: C (Rear Pivot), Bore Size: 125 (1 1/4"), Stroke: 0300 (3"), Cushion: C (Rubber Bumper), Rod Boot: Without Boot, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal