SMC Corporation of America
Elite Part Number Search
Search Results "NCDGBA50-1700-M9NL"

Model LEFB25 LEFB32 LEFB40 300, 400, 500 600, 700, 800 900, 1000, (1100) 1200, (1300, 1400) 1500, (1600, 1700) (1800, 1900), 2000 2500 300, 400, 500 600, 700, 800 900, 1000, (1100) 1200, (1300, 1400) 1500, (1600, 1700) (1800, 1900), 2000 2500, 3000 300, 400, 500 600, 700, 800 900, 1000, (1100) 1200, (1300, 1400) 1500, (1600, 1700) (1800, 1900), 2000 LEF Stroke [mm] Note 1) LEJ Actuator specifications

Three-phase type IDF TR 5 1700 Capacity Power supply voltage Type Symbol Capacity Outlet voltage Applicable air dryer IDF22E-30, IDF37E-30 IDU22E-30, IDU37E-30 IDF55E-30, IDF75E-30 IDU55E-30, IDU75E-30 Inlet voltage 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 380, 400, 415 VAC (50 Hz) 380 to 440 VAC (60 Hz) 440, 460 VAC (50 Hz) 440 to 500 VAC (60 Hz) 220, 240, 380, 400, 415, 440 VAC (50/60 Hz)

) (1800), (1900), 2000 50, 100, 150, 200, 250 300, 350, 400, 450, 500 550, 600, 700, 800, 900 1000, (1100), 1200, (1300) (1400), 1500, (1600), (1700) (1800), (1900), 2000 Stroke [mm] Note 1) Work load [kg] Note 2) Horizontal 10 20 Speed [mm/s] Note 2) 48 to 1000 (Refer to Table 1 for set values when LECP1 or 2 is selected.)

Lead wire length symbols:0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 12-13-25 for solid state switch with pre-wire connector. 12-5-4 5 2 Finger Rotary Actuated Air Gripper Series MHR2/MDHR2 30 Model/Specifications Nominal size 10 15 20 Action Double acting Gripping force (N) (1) External grip 12 24 33 58 (Effective value) at 0.5 MPa Internal grip 12 34

Lead wire length symbols: 0.5 m Nil (Example) M9N 1 m M (Example) M9NM 3 m L (Example) M9NL 5 m Z (Example) M9NZ MA D491 Series MHR2/MDHR2 Model/Specifications Nominal size 20 10 15 30 Double acting Action Gripping force (N) (1) External grip 33 12 58 24 (Effective value) at 0.5 MPa Internal grip 34 12 59 25 Finger closing width (mm) Finger opening width (mm) 16 10 19 14 Opening/ Closing

L M9NL 5 m . Z M9NZ Refer to page 731 for further information on auto switches. Order with an auto switch part number when ordering a single auto switch unit. Auto switches marked with a "" are made upon receipt of order.

Example) -M9NL Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.

Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 10-12-16 for details on other applicable auto switches than listed above.

, 12 V A93 A90 M9N M9P M9B F9NW F9PW F9BW A93V A90V M9NV M9PV M9BV F9NWV F9PWV F9BWV 2-wire Relay, PLC IC circuit 100 V or less No 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Grommet Relay, PLC Yes 24V 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL

Solid state switch Yes Yes Grommet Relay, PLC A93 A93V 2-wire 12 V 24 V 100 V M9N M9NV 3-wire (NPN) IC circuit 5 V, 12 V M9P M9PV 3-wire (PNP) Relay, PLC M9B M9BV 2-wire 12 V 24 V Grommet F9NW F9NWV 3-wire (NPN) 5 V, 12 V Diagnostic indication (2-color indication) F9PW F9PWV 3-wire (PNP) F9BW F9BWV 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL

Stroke Standard/Produced upon receipt of order 50 100 150 200 250 300 350 400 450 500 550 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 LEMB25 LEMB32 Please consult with SMC as all non-standard and non-made-to-order strokes are produced as special orders.

With earth leakage breaker With automatic water supply function 377 mm Applicable to DI water (deionized water) piping Variations Cooling capacity (W) Cooling method Power supply International standards Model HRS012 Air-cooled refrigeration Water-cooled refrigeration 1100/1300 (50/60 Hz) Single-phase 100 VAC (50/60 Hz), 115 VAC (60 Hz) Single-phase 200 to 230 VAC (50/60 Hz) CE/UL HRS018 1700

temperature 35 40 (C) IDFA Ambient temperature 32 (C) 10 (C) Outlet air pressure dew point IDFB Power supply voltage (frequency) Note 4) Single-phase/Three-phase: 200 VAC (50 Hz) Note 4) Single-phase/Three-phase: 200/220 VAC (60 Hz) Three-phase: 200 VAC (50 Hz) Three-phase: 200/220 VAC (60 Hz) ID Power consumption (W) 50/60 Hz 810/940 810/940 Single-phase 200 V 850/1070 850/1070 1300/1700

When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available.

When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available. Please contact SMC. 3) 14 to 194F (10 to 90C) for Vespel seat.

22bit encoder (Resolution: 4194304 p/rev) [With LECSC-T] Absolute 18bit encoder (Resolution: 262144 p/rev) specification Type Note 5) No excitation operating type Lock Holding force [N] 27 54 110 Power consumption [W] at 20Note 6) 6.3 7.9 7.9 Rated voltage [VDC] 24 0-10% Product Weight [kg] Model LEFB25 Stroke [mm] 300 400 500 600 700 800 900 1000 (1100) 1200 (1300) (1400) 1500 (1600) (1700

Min. operating pressure 5 to 60C (No freezing) 10 turns 10 turns 8 turns Ambient and fluid temperature Number of needle rotation Hexagonal lock nut With seal, Hexagonal lock nut, Nickel plated Option 181 106 64 29 10 6 3 Weight (g) 20 0.3 1700 26 920 14 460 7 230 3.5 105 1.6 Flow rate /min (ANR) Controlled flow (Free flow) Effective area (mm2) Note 1) Flow rate values are measured at 0.5

Min. operating pressure 5 to 60C (No freezing) 10 turns 10 turns 8 turns Ambient and fluid temperature Number of needle rotation Hexagonal lock nut With seal, Hexagonal lock nut, Nickel plated Option 181 106 64 29 10 6 3 Weight (g) 20 0.3 1700 26 920 14 460 7 230 3.5 105 1.6 Flow rate /min (ANR) Controlled flow (Free flow) Effective area (mm2) Note 1) Flow rate values are measured at 0.5

Three-phase type IDF TR 5 1700 Capacity Power supply voltage Symbol Applicable air dryer Capacity Symbol Inlet voltage Outlet voltage Type 1700 IDF22E-30, IDF37E-30 IDU22E-30, IDU37E-30 1.7 kVA 5 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 200 VAC (50 Hz) 200, 220 VAC (60 Hz) Threephase 6 380, 400, 415 VAC (50 Hz) 380 to 440 VAC (60 Hz) 4000 IDF55E-30, IDF75E-30 IDU55E-30, IDU75E-30 4 kVA 7000

Retainer prevents accidental loss of needle. 5 to 60C (No freezing) Ambient and fluid temperature Round lock nut With seal, Round lock nut, Nickel plated Option Weight (g) 181 106 64 29 10 6 3 Flow rate L/min (ANR) 105 230 460 920 1700 20 Controlled flow Free flow Sonic conductance dm 3/(sbar) 0.32 0.7 1.4 2.8 5.2 0.06 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 0.2 Free