or less 1200 or less Hard chrome plated stainless steel rod XC68 300 2400 or less 1200 or less Rod Boot Material Class 2 Pressure Vessel Maximum ambient temperature In the case of exceeding the following strokes, the cylinder is subject to Class 2 Pressure Vessel Act.
MK MB1 ML + Adjustable range 4 Stroke XC6 Standard model no.
Magnet: Built-in, Mounting: Front Flange, Bore Size: 4", Stroke: 24", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: -, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Mounting Basic Axial foot Rod flange Center trunnion Standard Rod end nut For parts made of stainless steel (-XC6), use the same specification stainless steel with the surface treatment (with hard chrome plated piston rod) (-XC68).
100 V, 200 V Solid state switch Reed switch 3-wire (NPN) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 4-wire (NPN) Terminal conduit 12 V Relay, PLC IC circuit Yes 5 V, 12 V With diagnostic output (2-color indicator) 24 V 12 V Grommet 5 V, 12 V Water resistant (2-color indicator) 12 V 5 V, 12 V With diagnostic output (2-color indicator) IC circuit A96 A93 A90 A54
E T Y P E MODEL OPERATING MAX CURRENT OR INDICATOR MODEL OPERATING MAX CURRENT OR INDICATOR NUMBER VOLTAGE OPERATING CURRENT LIGHT / WIRE NUMBER VOLTAGE OPERATING CURRENT LIGHT / WIRE MODEL BORE SIZE RANGE (MA) OUTPUT RANGE (MA) OUTPUT BT-12 500 (5 Bore) D-A53 24VDC 5~20MA YES D-F59 28VDC OR LESS 150MA 3 WIRE (NPN) 600 (6 Bore) 24VDC 5~20MA D-F5P 100MA 3 WIRE (PNP) BT-18A 800 (8 Bore) D-A54
E T Y P E MODEL OPERATING MAX CURRENT OR INDICATOR MODEL OPERATING MAX CURRENT OR INDICATOR NUMBER VOLTAGE OPERATING CURRENT LIGHT / WIRE NUMBER VOLTAGE OPERATING CURRENT LIGHT / WIRE MODEL BORE SIZE RANGE (MA) OUTPUT RANGE (MA) OUTPUT BT-12 500 (5 Bore) D-A53 24VDC 5~20MA YES D-F59 28VDC OR LESS 150MA 3 WIRE (NPN) 600 (6 Bore) 24VDC 5~20MA D-F5P 100MA 3 WIRE (PNP) BT-18A 800 (8 Bore) D-A54
Vertical Drive Graph (1)-2 Vertical Drive Supply Pressure 0.5 MPa 1000 Operating conditions Vertical drive Graph (1)-2 Load mass M = 5 kg Stroke St = 800 mm Time for stroke required To = 0.5 s 500 RHC100 196J RHC80 127J 100 RHC63 84J RHC50 47J Estimate of the maximum speed Load mass M (kg) 50 RHC40 33J Average stroke speed Vm = St/To = 1600 mm/s Maximum speed Vmax = 1.5 Vm = 2400 mm/s RHC32
(Example) A54 (Example) A54L (Example) A54Z Since there are other applicable auto switches than listed, refer to page 10-15-76 for details.
Lead wire length symbols: 0.5 mNil 3 m L 5 m Z (Example) A54 (Example) A54L (Example) A54Z Since there are other applicable auto switches than listed, refer to page 10-15-76 for details.
Auto switch can be mounted. 9 Series NCG/CG1 Water Resistant Precautions Style Bore size Stroke CG1 G5BAL R Mounting style -XC6 Be sure to read before handling. Refer Best Pneumatics for Safety Instructions and Actuator Precautions.
Double Rod M O U N T I N G N O O F S W I T C H E S B Basic C Single Clevis L Foot F Front Flange G Rear Flange U Front Trunnion T Rear Trunnion D Double Clevis N Front Nose Mount CONSTRUCTION SPECIFICATIONS 2 Pieces S 1 Piece n n number of switches Rod cover Aluminum alloy (Black Anodizing) O P T I O N S Body Aluminum alloy (Hard Alumite) XC6 Stainless Steel Rod XB6 High Temperature XB7 .
Double Rod M O U N T I N G N O O F S W I T C H E S B Basic C Single Clevis L Foot F Front Flange G Rear Flange U Front Trunnion T Rear Trunnion D Double Clevis N Front Nose Mount CONSTRUCTION SPECIFICATIONS 2 Pieces S 1 Piece n n number of switches Rod cover Aluminum alloy (Black Anodizing) O P T I O N S Body Aluminum alloy (Hard Alumite) XC6 Stainless Steel Rod XB6 High Temperature XB7 .
Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.
Symbol Specifications Change of rod end shape Special port location Made of stainless steel -XA -XC3 Mounting bracket Description (when ordering a minimum number) Bore size (mm) Minimum order 20 25 32 40 -XC6 Axial foot -XC9 2 CM-L020B CM-L032B Foot 2 pcs., Mounting nut 1 pc.
(in) Bore size Standard Stroke 1.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 2, 2.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 3.25, 4 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How To Order MOUNTING BORE STROKE SUFFIX XC6 NCDA1 Ex: NCDA1B 150-0400-XC6 Auto-switch capable Stainless Steel Rod Low Speed Specifications Bore size (inch) 1.5 2 2.5 3.25 4 Media Max.
Symbol Specifications -XAl Change of rod end shape -XC3 Special port location -XC6 Made of stainless steel Mounting bracket Min. order q'ty Bore size (mm) Contents (for minimum order quantity) 20 25 32 40 Axial foot* 2 CM-L020B CM-L032B CM-L040B 2 foots, 1 mounting nut Flange 1 CM-F020B CM-F032B CM-F040B 1 flange Single clevis** 1 CM-C020B CM-C032B CM-C040B 1 single clevis, 3 liners -XC9
Standard Stroke CM2 Standard stroke 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 Bore size (in) 1.50 2, 2.50 3.25, 4 CG1 MB How to Order MB1 NC D A1 Mounting Bore Stroke Suffix XC6 CA2 Ex: NCDA1B 150-0400-XC6 CS1 Auto switch capable Stainless steel rod C76 C85 Low Speed C95 Specifications CP95
Indicator light Lead wire length (m) Note) Load voltage Wiring (Output) Special function Type Electrical entry Applicable load Connector Auto switch model 0.5 (Nil) 3 (L) 5 (Z) AC DC CJ1 100 V, 200 V A53 A54 PLC 24 V 2-wire 12 V Relay, PLC Reed switch Solid state switch Yes CJP 3-wire (Equiv.
Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 2400 (24"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)