SMC Corporation of America
Elite Part Number Search
Search Results "NCDA1F400-1600-A64-XC6"

are the same as the standard double acting, single rod type. 40, 50, 63, 80, 100 Bore size (mm) Air cushion Cushion DAuto switch mounting Tie-rod mounting -X Piston rods, rod end nuts made of stainless steel (-XC6) Made to order Individual -X Specifications other than the above are the same as the standard basic type.

-XC65 XC6 + XC7 specifications -X1184 Cylinder with reed, heat-resistant switch Mounting Bracket Part No. Refer to pages 322 and 327 for cylinders with auto switches.

Unit: mm Maximum stroke Bore size (mm) Basic type, Rear flange type, Single clevis type, Double clevis type, Center trunnion type Foot type, Front flange type to 1400 (to 1600) to 1000 (to 1000) 125, 140 160 to 1400 (to 1600) to 1200 (to 1200) Auto switches are not available with steel tubing.

Mounting Basic Axial foot Rod flange Center trunnion Standard Rod end nut For parts made of stainless steel (-XC6), use the same specification stainless steel with the surface treatment (with hard chrome plated piston rod) (-XC68).

Weight (g) D-A53 D-A54 D-A56 D-A64 D-A67 Auto switch model 0.5 m (Nil) 3 m (L) 5 m (Z) 24 48 96 24 48 24 48 Lead wire length Dimensions (mm) 6 14 6 4.5 5 12 22 Indicator light 12 33 D-A64/A67 without indicator light DD4 16 11 16 Most sensitive position 1639 Reed Auto Switch Tie-rod Mounting Style D-A33C/D-A34C/D-A44C Refer to SMC website for the details of the products conforming to the

Maximum Stroke [mm] Double acting, Single rod Double acting, Double rod 32: 1000 40 to 100: 1700 125: 1600 1000 (Same as standard type) Specifications Parts changed to stainless steel Piston rod, Rod end nut Other specifications and external dimensions Same as standard type Standard model no.

Auto switch can be mounted. 9 Series NCG/CG1 Water Resistant Precautions Style Bore size Stroke CG1 G5BAL R Mounting style -XC6 Be sure to read before handling. Refer Best Pneumatics for Safety Instructions and Actuator Precautions.

Series Maximum Stroke (mm) Double acting, Single rod Double acting, Double rod CP96 32: 1800 40 to 100: 1700 125: 1600 1000 (Same as standard type) C96 32: 1000 40 to 100: 1700 125: 1600 1000 (Same as standard type) Specifications Parts changed to stainless steel Piston rod, Rod end nut Other specifications and external dimensions Same as standard type How to Order XC68 Standard model no.

(in) Bore size Standard Stroke 1.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 2, 2.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 3.25, 4 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How To Order MOUNTING BORE STROKE SUFFIX XC6 NCDA1 Ex: NCDA1B 150-0400-XC6 Auto-switch capable Stainless Steel Rod Low Speed Specifications Bore size (inch) 1.5 2 2.5 3.25 4 Media Max.

Bore size (mm) Foot style, Rod side flange style ML1C 125, 140 160 Up to 1000 Up to 1000 Up to 1600 Up to 1200 Up to 1200 Up to 1600 Cylinder Stroke/Auto Switch Mounting on Cylinder Unit (Built-in Magnet) Refer to the minimum auto switch mounting stroke (page 774) for those with an auto switch.

-X Maximum stroke Bore size (mm) Basic style, Head side flange style, Single clevis style, Double clevis style, Center trunnion style Foot style, Rod side flange style 20125, 140 160 Up to 1000 (Up to 1000) Up to 1400 (Up to 1600) Data Up to 1200 (Up to 1200) Up to 1400 (Up to 1600) Auto switches are not available with iron tube.

D-A72(H) must be used with the contact protection box regardless of load styles and lead wire length. 2 Please contact SMC when using built-in contact protection circuit style (DA34[A][C], D-A44[A][C], D-A54/A64, D-B54/B64, D-A59W, D-B59W) in the following conditions: 1. The wiring length to load is more than 30 m; 2. When using PLC with large flow current.

3 5 30 46 M14 x 1.5 161 78 18 110 146 128 16 114 64 110 100 298 112 246 27 Up to 1400 1401 to 1600 M16 x 1.5 182 95 23 132 169 144 18.5 130 74 120 106 338 118 275 30.5 Up to 1400 1401 to 1600 5 5.5 6 30 34 42 16 21 35 M18 x 1.5 204 106 36 167 195 162 18.5 149 86 135 125 398 132 320 35 1801 to 2000 Up to 1800 118 226 124 40.5 187 216 182 18.5 165 97 135 M20 x 1.5 132 418 150 348

Mounted directly to unlocking port Maximum value from range of 100 measured stopping positions 125, 140 1600 or less 1000 or less 1000 or less 160 1600 or less 1200 or less 1200 or less 180 2000 or less 1200 or less Class 2 Pressure Vessel 200 2000 or less 1200 or less A class 2 pressure vessel will be required for strokes exceeding those shown below. 250 2400 or less 1200 or less Cylinder

Class B or equivalent (130C) Coil insulation 100 VA 50 Hz Inrush Symbol Specifications 90 VA 60 Hz AC Apparent power Note) -XA Change of rod end shape 20 VA 50 Hz Holding -XC4 With heavy duty scraper 14 VA 60 Hz Piston rod and rod end nut made of stainless steel Note) Power consumption 13.2 W DC -XC6 Note) At the rated voltage.

Class B or equivalent (130C) Coil insulation 100 VA 50 Hz Inrush Symbol Specifications 90 VA 60 Hz AC Apparent power Note) -XA Change of rod end shape 20 VA 50 Hz Holding -XC4 With heavy duty scraper 14 VA 60 Hz Piston rod and rod end nut made of stainless steel Note) Power consumption 13.2 W DC -XC6 Note) At the rated voltage.

2 5.4-28 -XC6 Piston rod and rod end nut made of stainless steel !3 5.4-29 -XC7 Tie rod, cushion valve, tie rod nut, etc. made of stainless steel !4 5.4-30 -XC8 Adjustable stroke cylinder/Adjustable extend stroke !5 5.4-36 -XC9 Adjustable stroke cylinder/Adjustable retract stroke !6 5.4-41 -XC10 Dual stroke cylinder/Double rod !

1400 or less 1600 or less Order Made Made to Order Mounting Bracket Part No.

MK MB1 ML + Adjustable range 4 Stroke XC6 Standard model no.

wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 4-wire (NPN) 3-wire IC circuit Terminal conduit 5 V, 12 V 12 V Relay, PLC Yes IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 24 V 12 V Grommet IC circuit 5 V, 12 V Water resistant (2-color indication) IC circuit 12 V 5 V, 12 V Diagnostic indication (2-color indication) A96 IC circuit 5 V Yes (NPN equivalent) A93 A90 A54 A64