The MXP is ideal for applications that require high precision movement in short travel situations. The precision slide table has a machined guide with very tight tolerances that operates in conjunction with highly accurate recirculating ball bearings. This slide is capable of achieving parallelism within 0.02mm and non-rotation accuracy as low as 0.03 degrees. Two of the mounting surfaces
The MXP is ideal for applications that require high precision movement in short travel situations. The precision slide table has a machined guide with very tight tolerances that operates in conjunction with highly accurate recirculating ball bearings. This slide is capable of achieving parallelism within 0.02mm and non-rotation accuracy as low as 0.03 degrees. Two of the mounting surfaces
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 10MM MXP DBL-ACTING AUTO-SW, ACTUATOR, MXP GUIDED CYLINDER, EE, 10MM MXP DBL-ACTING AUTO-SW, 0.45033 lb
Piston rod Table (2) MXP6 MXP10/12/16 L2 L2 L2 (mm) 10 (One side only) 10 (One side only) 9 8 8 8 8 8 Model MXP6-5C MXP6-10C MXP10-10C MXP10-20C MXP12-15C MXP12-25C MXP16-20C MXP16-30C Damage is not allowed. 3. Shock absorber is considered a consumable component. When energy absorption is decreased, replace it.
L SPECIFICATIONS Fluid Air S T D S T R O K E/H U N D R E D T H S O F A N I N C H Proof Pressure 1MPa / 145 PSI 6 (1/4) 050, 100, 150, 200 10 (3/8) 050. 100. 150, 200, 300, 400, 500, 600 16 (5/8) 050, 100, 150, 200, 300, 400, 500, 600, 700, 800 MaxImum Operating Pressure 0.7MPa / 100 PSI 6 0.1MPa / 17 PSI Minimum Operating Pressure 10, 16 0.05MPa / 8.5 PSI Ambient and Fluid Temperature -10C
L SPECIFICATIONS Fluid Air S T D S T R O K E/H U N D R E D T H S O F A N I N C H Proof Pressure 1MPa / 145 PSI 6 (1/4) 050, 100, 150, 200 10 (3/8) 050. 100. 150, 200, 300, 400, 500, 600 16 (5/8) 050, 100, 150, 200, 300, 400, 500, 600, 700, 800 MaxImum Operating Pressure 0.7MPa / 100 PSI 6 0.1MPa / 17 PSI Minimum Operating Pressure 10, 16 0.05MPa / 8.5 PSI Ambient and Fluid Temperature -10C
B -X51 MXP6 Standard product 2.4 2.4 Z 2-plugs: M-3P -X23 (mm) Z 2-hexagon socket set screws: M3 A 20 20 25 B 10.5 9 12 C 8 9 10 D 4.5 5 6 Model MXP10--X51 MXP12--X51 MXP16--X51 (mm) Z 45 60 Model MXP6-5-X23 MXP6-10-X23 MXP10/12/16 Standard products 2-plugs: M-5P 3 3 Z -X23 Z 2-hexagon socket set screws: M5 x 4 (mm) Z 60 90 76 106 102 128 Model MXP10-10-X23 MXP10-20-X23 MXP12-15-X23 MXP12
, D-M9N Stroke (mm) Auto switch operating range 10 34.5 35.5 14.5 15.5 Stroke (mm) Auto switch operating range 10 30.5 31.5 18.5 19.5 Model Model 5 25.5 26.5 13.5 14.5 A B C D A B C D 11-/22-MXP6 5 11-/22-MXP6 3 11-/22-MXP10, 12, 16 Electrical entry from outside Electrical entry from inside Parallel electrical entry B A B B A A Solid state auto switch D-M9B, D-M9N Reed auto switch D-A93
3 11-/22-MXP 6 5 11-/22-MXP10, 12, 16 Electrical entry from outside Electrical entry from inside Parallel electrical entry B A B B A A Solid state switch D-M9B, D-M9N Reed switch D-A93 (mm) (mm) Stroke (mm) 20 41 29 47 35 Stroke (mm) 20 45 25 51 31 Auto switch operating range Auto switch operating range 15 40.5 20.5 Model Model 25 50.5 30.5 30 59 39 10 35 15 25 46.5 34.5
Type MXP8 MXP10 MXP12 MXP16 Tightening torque joint shaft 0.4 Nm 0.7 Nm 1.8 Nm 3.6 Nm Note 1) Assemble end plate so that A, B dimensions will be values on table below. (mm) A B Type MXP8 Body (Note 1) 0.2 0.2 MXP10 End plate (Note 1) MXP12 0.5 0.3 MXP16 Bolt torque 0.45 Nm Type MXP8 MXP10 MXP12 MXP16 A 0.6 Nm B 1.4 Nm 12. Remove the end plate mounting bolt on the opposite side. 13.
INDEX 362 Series CJ2 Specifications Bore size (mm) 6 10 16 Action Double acting, Single rod Fluid Air Proof pressure 1 MPa Maximum operating pressure 10.7 MPa Minimum operating pressure Rubber bumper 0.12 MPa 0.06 MPa Air cushion 0.1 MPa Ambient and fluid temperature Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C Cushion Rubber bumper Rubber bumper/Air cushion
Stroke (mm) Stroke adjusters Auto switch 10 15 20 25 30 Series 5 Metal stopper Rubber stopper Shock absorber Metal stopper Shock absorber MXP6 Lock plate MXP10 MXP12 MXP16 Using lock plates to securely lock the adjustment bolt with minimal force.
Symbol 1 Heat Resistant Cylinder (10 to 150C) -XB6 Air cylinder which changed the seal material and grease, so that it could be used even at higher temperature up to 150 from 10C.
-X 141 CJ2Y Series Specifications Bore size (mm) 10 16 Action Double acting, Single rod Fluid Air Proof pressure 1.05 MPa Maximum operating pressure 10.7 MPa Ambient and fluid temperature Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C Cushion Rubber bumper (Standard equipment) Lubrication Not required (Non-lube) Stroke length tolerance +1.0 0 Piston speed 5 to
Minimum operating pressure 0.05 MPa Ambient and fluid temperature Without auto switch: 10C to 70C (No freezing) With auto switch : 10C to 60C Because it is a directly mounted type without using brackets, its overall length is shorter, and its installation pitch can be made smaller. Thus, the space that is required for installation has been dramatically reduced.
2-wire 12 V Water resistant (2-color indication) MRHQ F9BA Lead wire length symbols: 0.5 m Nil (Example) M9B 3 m L (Example) M9BL 5 m Z (Example) M9BZ Auto switches marked with a symbol are produced upon receipt of order.
Weight (g) End boss type (Symbol) Model H E M K MHZA2-6 28 28 28 28 MHZAJ2-6 29 29 29 29 12-2-24 24 Parallel Style Air Gripper Standard Type Series MHZ2 Size: 6, 10, 16, 20, 25, 32, 40 How to Order MHZ 6 MHZ2 D 6 M9B MHF MHL Number of auto switches Number of fingers 2 2 fingers Nil S 2 pcs. 1 pc.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F MHZ2-10C/MHZL2-10C MHZ2-32C 250 Pressure 0.7 MPa Pressure 0.7 MPa Pressure Internal Grip Pressure 0.7 MPa Pressure 0.7 MPa 20 0.6 MPa 0.6 MPa 200 MHZA2, MHZ2, MHZL2 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 15 0.5 MPa 0.5 MPa 0.5 MPa 0.5
1 series 10C 20C 30C Standard model (Normal operation) Set dew point Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 10 to 30C. 2. Normal operation (ECO LED is OFF): Dew point is fixed to 10C. Description No.
Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item Bore size Suction flow rate L/min (ANR) 20/25/32/40 50/63/80/100 20 25 32 40 50 63 80 100 10 20 1.5 MPa 1.0 MPa 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Stroke