Adjuster Type: Metal Stopper w/Bumper, Both Ends, Bore Size: 12mm, Stroke: 50, Mounting Bolt: for Adjustment Plate and Switch Rail Mounting
Adjuster Type: Shock Absorber, Both Ends, Bore Size: 16mm, Stroke: 50, Mounting Bolt: for Adjustment Plate and Switch Rail Mounting
Adjuster Type: Metal Stopper, Both Ends, Bore Size: 12mm, Stroke: 10, Mounting Bolt: for Adjustment Plate Mounting
Adjuster Type: Metal Stopper, Both Ends, Bore Size: 16mm, Stroke: 50, Mounting Bolt: for Adjustment Plate and Switch Rail Mounting
Adjuster Type: Shock Absorber, Both Ends, Bore Size: 16mm, Stroke: 50, Mounting Bolt: for Adjustment Plate Mounting
For use with the MXJ 12mm and 16mm bore MXJ compact slide tables. Bore sizes: 12, 16mm; Use to easily mount direct mount auto switches
For use with the MXJ 12mm and 16mm bore MXJ compact slide tables. Bore sizes: 12, 16mm; Use to easily mount direct mount auto switches
The MXP is ideal for applications that require high precision movement in short travel situations. The precision slide table has a machined guide with very tight tolerances that operates in conjunction with highly accurate recirculating ball bearings. This slide is capable of achieving parallelism within 0.02mm and non-rotation accuracy as low as 0.03 degrees. Two of the mounting surfaces
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SWITCH RAIL, ACTUATOR, MXP GUIDED CYLINDER, F1, 12MM MXP PART, .04840 lb
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., Adjuster, GUIDED
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., METAL STOPPER,
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., ADJUSTER, GUIDED
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., METAL STOPPER,
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., ADJUSTERS, SHOCK
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., ADJUSTERS, SHOCK
The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., SHOCK ABSORBER,
0 to 50C Linearity Note 1) 5% F .S. or less 3% F .S. or less Repeatability Note 1) 2% F .S. or less 1% F .S. or less Temperature characteristics 2% F.S. or less (15 to 35C based on 25C), 3% F .S. or less (0 to 50C based on 25C) Pulse output, N channel, open drain, output for display unit PF2W3.
0 to 50C Linearity Note 1) 5% F.S. or less 3% F.S. or less 1% F.S. or less (connected with PF2W33) Repeatability Note 1) 3% F.S. or less 3% F.S. or less (connected with PF2W2) 2% F.S. or less (15 to 35C based on 25C), 3% F.S. or less (0 to 50C, based on 25C) Temperature characteristics Pulse output, N channel, open drain, output for display unit PF2W3.
Inlet air temperature 5 to 50C IDF (For IDF100F to 150F, up to 60C is allowed.)
Note 2) Power supply 12 months continuous operation (without back lighting) Battery life 250ms Response speed 2% F.S. or less (Temperature conditions: at 25C) Display accuracy 1% F.S. or less (Temperature conditions: at 25C) Repeatability 3% F.S. or less (0 to 50C, based on 25C) Temperature characteristics M5 x 0.8 Piping port 0 to 50C (with no condensation) Ambient temperature 35 to 85%