(Tightening torque of DIN rail holding screw: 0.5 Nm) t y u EX500 (Type 10SAW) r Note) i D-sub connector (Type 10F) r is not included in the SUP/EXH block assembly. o EX126 (Type 10S4D) EX120 (Type 10S3) For flat ribbon cable connector (Type 10P) !1 o and !0 are not included in the SUP/EXH block assembly. !0 !1 is not included in the SUP/EXH block assembly. Note) i and !
P + 0.1 0.1 QCR = 2V x x 10P 0.1 QCP = 2 x a x l x x 10QC = QCR + QCP Formula QC2 = QC x n x Number of actuators x Reserve factor QCR = Air consumption of Mini-Rotary Actuator [l (ANR)] QC2 = Compressor discharge flow rate n = Actuator reciprocations per minute QCP = Air consumption of tubing or piping [l (ANR)] V = Internal volume of Mini-Rotary Actuator [cm] Internal cross section of tubing
One-touch fitting for 12 SV4000 NPT 3/8 SV4000 Rc 3/8 NPTF 3/8 G 3/8 A, B ports mixed A, B ports mixed 1-2-77 74 Series SV Manifold Electrical Wiring 10P/16P Flat Ribbon Cable Type (26 pins) 10PG/16PG Flat Ribbon Cable Type (20 pins) Common Common Common Common 20 26 19 25 SOL.B SOL.B Station 9 Station 12 18 24 SOL.A SOL.A 17 Light/Surge voltage suppressor 23 Light/Surge voltage suppressor
S kit (Serial transmission) Kit F kit (D-sub connector) T kit (Terminal block) P kit (Flat cable connector) F 25P U S P 26P U S F 15P U S A S U S P 16P U S B P 20P U S C P A 10P Model T1 T2 (1) (1) (1) Max. number 16 14 16 16 14 8 8 16 16 Note 1) Due to the limitation of internal wiring.
P + 0.1 0.1 QCR = 2V x x 10P 0.1 QCP = 2 x a x l x x 10QC = QCR + QCP Formula QC2 = QC x n x Number of actuators x Reserve factor QCR = Air consumption of Mini-Rotary Actuator [l (ANR)] QC2 = Compressor discharge flow rate n = Actuator reciprocations per minute QCP = Air consumption of tubing or piping [l (ANR)] V = Internal volume of Mini-Rotary Actuator [cm] Internal cross section of tubing
External pilot type (R) X, PE port sizes are 4 (metric), 5/32" (inch) for the 10-SV1000/2000 series and 6 (metric), 1/4" (inch) for the 10-SV3000/4000 series. 252 Flat Ribbon Cable Connector 10-SV Manifold Electrical Wiring 10P/16P flat ribbon cable type (26 pins) 10PG/16PG flat ribbon cable type (20 pins) Common Common 26 20 25 19 Station 12 SOL.b Station 9 SOL.b 24 18 SOL.a SOL.a 23 17
[Please refer to the following pages of the catalog]P.75 Cylinder bore ø4-10P.76 Cylinder bore ø12-20
Plate Material: A (Aluminium Alloy), Bearing Type: M (Slide Bearing), Bore Size: 16mm, Port Thread Type: Rc (Or M5x0.8 for 12,16 Bore), Stroke: 10mm, Piping Port Location: P (Top Ported)
Plate Material: A (Aluminium Alloy), Bearing Type: M (Slide Bearing), Bore Size: 12mm, Port Thread Type: Rc (Or M5x0.8 for 12,16 Bore), Stroke: 10mm, Piping Port Location: P (Top Ported)
Stroke: 10mm, Rod End: Rod End Female Thread, Piping: P (Top Ported)
Bore Size: 12mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)
Bore Size: 16mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)
Bore Size: 25mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)
Bore Size: 20mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)
Bore Size: 16mm, Symmetric Type: L (Symmetric), Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)
Bore Size: 20mm, Symmetric Type: L (Symmetric), Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)
Bore Size: 8mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)
Bore Size: 6mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)
Bore Size: 8mm, Symmetric Type: L (Symmetric), Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)
Bore Size: 6mm, Symmetric Type: L (Symmetric), Stroke: 10mm, Adjuster: w/o Adjuster, Function: P (Axial Piping)