SMC Corporation of America
Elite Part Number Search
Search Results "MS-5P"

(mm) 4 Translucent (N) 250 m reel 500 m reel Specifications Fluid Air, Water Note 1), Inert gas Applicable fittings Note 2) One-touch fittings, Insert fittings Fluoropolymer fittings: Series LQ Miniature fittings: Series M, MS (Hose nipple type) Operating Temperature: Max. 200C It varies depending on the operating pressure.

50 ms PNP 2 output type LFElBlll Brown DC (+) Black OUT1 Max. 80 mA Load White OUT2 0 V or Load 50 ms 50 ms * When accumulated pulse output is selected, the indicator light is turned off.

SQ (Metal seal, single, with indicator light/surge voltage suppressor) VQ0 VQ0 10 ms Space-saving 45% less 200 million cycles VQ1000 10 ms VQ4 Capacity-saving 50% less VQ2000 20 ms Dispersion accuracy 2 ms VQ5 VQZ Thin compact design with large flow capacity VQD VQ0 (VV5Q05) Locking type (Manual) Flow characteristics Locking type manual override Ejector unit Built-in silencer, direct exhaust

s/2 s (linked with the switch output) Voltage output: 1 to 5 V Output impedance: 1 k7 Voltage output Current output Analog output Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDC Hysteresis External input Display method Indicator light Power supply voltage Current consumption Variable Voltage free input: 0.4 V or less (Reed or Solid state), input for 30 ms

or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms) Yes 0.2% F.S. 1 digit Push Push Push Push Push Push Finish setting Adjust to set-value with buttons.

Auto switch operating range (mm) _ Load operation time (ms) V(mm/s) = x 1000 4. Keep wiring as short as possible. As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the products life.

(Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms) ZSP Short circuit protection With short circuit protection 0.5%F.S.

Response time 1 ms 1 ms Able to set the 4 patterns of the display color.

female x M5 female x M5 male 4/2.5 x M5 MS-5AU-4 MS-5UT For piping soft nylon and polyurethane tubing Reducer bushing Connects Rc 1/8 to M5 fitting MS-5B R 1/8 x M5 female 6/4 x M5 MS-5AU-6 For piping soft nylon tubing For piping polyurethane tubing Plug Barb elbow for soft tube 3.18/2.18 x M5 Closes the unused M5 port MS-5P MS-5ALHU-3 3.18/2 x M5 Unrestricted 360 positioning and fastening

female x M5 female x M5 male 4/2.5 x M5 MS-5AU-4 MS-5UT For piping soft nylon and polyurethane tubing Reducer bushing Connects Rc 1/8 to M5 fitting MS-5B R 1/8 x M5 female 6/4 x M5 MS-5AU-6 For piping soft nylon tubing For piping polyurethane tubing Plug Barb elbow for soft tube 3.18/2.18 x M5 Closes the unused M5 port MS-5P MS-5ALHU-3 3.18/2 x M5 Unrestricted 360 positioning and fastening

New New Compact Vacuum Unit Ejector/Vacuum Pump System RoHS Air consumption: 17% reduced 17% 17% 17% 21% 21% 21% Response time of the valve: 21% increased 5 m ms 5 ms Quick response Energysaving Vacuum pressure reached: 25% 28 ms ms Vacuum response time: 28 ms Compared with existing model (Shortened by 25%; Comparison with other SMC products) 0.88 14.5 Air consumption SCFM (L/min (ANR))

Response time settings: 20 ms, 160 ms, 640 ms, 1280 ms This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.

or above (Pulse input) Counting Speed 20 Kcps External Power Supply 12V10%, 60mA Control Output CEU1-D: NPN (30VDC, 50mA) CEU1P-D: PNP (30VDC, 50mA) Output Mode Comparison/hold/one-shot (100 ms fixed) Supply Voltage 24VDC 10% Output Delay Time 5 ms max Power Consumption 10VA Weight 250g H O W T O O R D E R S E E N E X T P A G E A P P L I C A T I O N S S E E N E X T P A G E Courtesy of

Response time settings: 20 ms, 160 ms, 640 ms, 1280 ms This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch.

Chattering-proof func. working: 20 ms, 160 ms, 640 ms, 1280 ms selected Repeatability 0.1%F.S. Voltage output 2 Output voltage: 1 to 5 V (within rated pressure range), Output impedance: approx.1 k Linearity: 0.2%F.S. (Without sensor), Response time: 150 ms or less Analogue output Accuracy 0.6%F.S. 1.0%F.S. 1.5%F.S.

Note 5) Set to 1.5 s (90%), can be changed to 100 ms. Note 6) Set to hystresis mode at the time of shipment from the factory.

Wireless communication signal Response time: 5 ms From the remote power supply ON to start of communication: Min. 250 ms MCommunication cables not required MNumber of I/O points MCompatible protocols Reduced wiring work, space, and cost Minimized disconnection risk Max. 1280 inputs/1280 outputs (Max. 128 inputs/128 outputs per module) Application Examples For tool changing For spot welding

0.05 L/pulse 0.1 L/pulse 0.5 L/pulse 1 L/pulse 2 L/pulse L/minL 0.5F.S. 0.5F.S. 0.5F.S. 0.5%F.S.(25 ) 9.9 L 9 L 1 0.1L 0.5L 1L NPN PNP 80 mA DC28 V NPN1 V (80 mA ) PNP1.5 V (80 mA ) 2 1 s/2 s 3 1 s/2 s 15 V 1 k 420 mA DC12 V 300 DC24 V 600 -66No.PF-OMN0011CN-C PF3W30 0.4 V ()30 ms / 2 4 7 2 /6 11 ) 5 / 12 DC1224 V10 50 mA 5P 4P (e-con) IP40( IP65) 050 () 3585R.H

Connection Power supply output 5P connector, sensor connection 4P connector (e-con) Enclosure IP40 (Note that the display front is only certified as IP65 by using optional parts (panel mount adapter and waterproof seal)). Operating temp. range 0 to 50 oC (No freezing and condensation) Environment Operating humidity range Operation, Storage: 35 to 85%R.H.