This is a legacy product, and replaced byCDM2E32-125AZ, CYL, RND BODY, AIR-CUSHION, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, LE, 32MM CM2 DBL-ACT AUTO-SW, 3.27452 lb
This is a legacy product, and replaced byCDM2B20-125AZ, CYL, RND BODY, AIR-CUSHION, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, HE, 20MM CM2 DBL-ACT AUTO-SW, .75232 lb
This is a legacy product, and replaced byCDJ2B16-125AZ-B, CYL, RND BODY, DBL ACT, W/O-SW, ACTUATOR, CJ2 ROUND BODY CYLINDER, GE, 16MM CJ2 DBL-ACT AUTO-SW, .33827 lb
This is a legacy product, and replaced byMGPM20-125AZ-A93L, CYL, GUIDE W/AIR CUSH,SLIDE BR, ACTUATOR, MGP COMPACT GUIDE CYLINDER, HM, 20MM MGP SLIDE BEARING, 3.87477 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520025030035040020MGPM20?0.67?0.750.830.911.171.371.571.761.962.162.633.033.423.82
This is a legacy product, and replaced byMGPM32TF-125AZ, CYL, GUIDE W/AIR CUSH,SLIDE BR, ACTUATOR, MGP COMPACT GUIDE CYLINDER, LM, 32MM MGP SLIDE BEARING, 7.59492 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520025030035040032MGPM32??1.69??2.072.472.853.243.624.004.385.336.096.867.62
This is a legacy product, and replaced byMGPM25-125AZ, CYL, GUIDE W/AIR CUSH,SLIDE BR, ACTUATOR, MGP COMPACT GUIDE CYLINDER, IM, 25MM MGP SLIDE BEARING, 5.14380 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520025030035040025MGPM25?0.95?1.051.161.271.651.922.192.472.743.013.674.214.765.30
This is a legacy product, and replaced byCDM2E25-125AZ-M9N, CYL, RND BODY, AIR-CUSHION, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, .93083 lb
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Bearing Type: L (Ball Bushing), Bore Size: Ø40 mm, Port Thread Type: Bore 16: M5 x 0.8; Bore 20-100: Rc, Stroke: 125 mm
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Bearing Type: L (Ball Bushing), Bore Size: Ø40 mm, Port Thread Type: Bore 16: M5 x 0.8; Bore 20-100: Rc, Stroke: 125 mm, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L [3m]
Bearing Type: L (Ball Bushing), Bore Size: Ø40 mm, Port Thread Type: Bore 16: M5 x 0.8; Bore 20-100: Rc, Stroke: 125 mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SDPC [0.5m Cord Length, M12-4 Pin Connector]
Bearing Type: L (Ball Bushing), Bore Size: Ø40 mm, Port Thread Type: Bore 16: M5 x 0.8; Bore 20-100: Rc, Stroke: 125 mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: SAPC [0.5m Cord Length, M8-3 Pin Connector]
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 0.5, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93V, Lead Wire Length(m): 3, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9N, Lead Wire Length(m): 0.5, The number of the switches
Bearing Type: L (Ball Bushing), Bore Size: Ø40 mm, Port Thread Type: Bore 16: M5 x 0.8; Bore 20-100: Rc, Stroke: 125 mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SBPC [0.5m Cord Length, M8-4 Pin Connector]
Bearing Type: Ball Bushing, Bore Size: Ø40 mm, Port Thread Type: Bore 16: M5 x 0.8; Bore 20-100: Rc, Stroke: 125 mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SBPC [0.5m Cord Length, M8-4 Pin Connector], Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 0.5, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: A93V, Lead Wire Length(m): 3, The number of the switches