SMC Corporation of America
Elite Part Number Search
Search Results "LEY40C-250M"

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 12.12542 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 8.99485 lb

Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed [mm] Model L A B n D E Without lock With lock LEFS40Em-150m 506 555 156 328 4 150 LEFS40Em-200m 556 605 206 378 6 2 300 LEFS40Em-250m 606 655 256 428 6 2 300 LEFS40Em-300m

53 Horizontal work load [kg] 80 Vertical work load [kg] 40 Lead 4: LEY40C 60 Lead 8: LEY40B Lead 8: LEY40B 27 40 20 30 Lead 16: LEY40A 13 20 Lead 16: LEY40A 0 0 0 300 400 500 200 100 600 0 300 400 500 200 100 600 Speed [mm/s] Speed [mm/s] 225 LEY Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Refer to page 224 for the LECP6, LECP1, LECPMJ, and page 225 for the LECPA.

Setting of response delay time Set range is 0 to 250m sec. to Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once. The set screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 24.

Table 5.3-12 List of set values Set values Explanation Initial value (Default setting) Setting/checking are not available unless the serial protocol setting is simple communication protocol. to Setting of response delay time Set range is 0 to 250m sec. Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once.

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY40C-200, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: DIN rail mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY40C-50, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Screw Clearance Hole, Rear Mount, Body

Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Without Built-in Magnet, Support bracket: Both Ends Tapped, Body Options

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Both Ends Tapped, Body Options: Male

Cylinder (Tube) Inner Diameter(φ): 1 1/2", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Male Rod

Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Through hole, Body Options: Male Rod End

Cylinder (Tube) Inner Diameter(φ): 3/4", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Rear Clevis, Body Options: Male Rod End

Cylinder (Tube) Inner Diameter(φ): 3", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Rear Clevis, Body Options: Male Rod End

Cylinder (Tube) Inner Diameter(φ): 1 1/16", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Rear Clevis, Body Options: Male Rod

Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 2 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Screw Clearance Hole, Rear Mount, Body