Size: 40, Motor Mounting Position: Top Mounting, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEY16: 2.5mm; LEY25: 3mm; LEY32/40: 4mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female Rod End, Mounting: Ends Tapped (Standard), Actuator Cable Type: Robotic Cable, Flexible Cable, Cable Length: 1.5m, Controller/Driver Type: -, I/O Cable Length: -, Protocol: -, Suffix:
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 9.5901 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 100, Motor Mounting Position: Top Side Parallel, Motor Type: T9 (AC Servo Motor, Absolute Encoder), Lead: L (2mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread), Mounting: D (Double Clevis)
Size: 32, Motor Mounting: L (Left Side Parallel Type), Motor Type: T7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 100mm, Motor Option: B (w/Lock), Rod End: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: D (Double Clevis)
Size: 32, Motor Mounting: R (Right Side Parallel Type), Motor Type: T7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 100mm, Motor Option: B (w/Lock), Rod End: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: D (Double Clevis)
Size: 32, Motor Mounting: Top Mounting Type, Motor Type: T7 [AC Servo Motor, (Absolute Encoder), Output 200W], Lead: C [LEY25, 3mm; LEY32, 4(5)mm], Stroke: 100mm, Motor Option: B (w/Lock), Rod End: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: D (Double Clevis)
Accuracy: H (High Precision), Motor Mounting Position: R (Right Side Parallel), Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: C (5mm), Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: D (Double Clevis)
Size: 40, Motor Mounting Position: L (Left), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis)
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis)
Size: 40, Motor Mounting Position: R (Right), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: D (Double Clevis)