Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 400mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC:
BAR NOZZLE, 400M, OTHERS, IZS/IZF IONIZER, 22, IZSE30 NO SIZE RATING
BENDER TUBE NOZZLE, 400M, OTHERS, IZS/IZF IONIZER, 22, IZSE30 NO SIZE RATING
LONG NOZZLE, 400M, OTHERS, IZS/IZF IONIZER, 22, IZSE30 NO SIZE RATING
Encoding system MRZI Transmission path format Bus format (conforming to EIA RS485) CC-Link Error control system CRC (X16+X12+X5+1) Connection cable CC-Link Ver.1.10-compliant cable (Shielded 3-core twisted pair cable) Transmission format Conforming to HDLC Remote station number 1 to 64 Communication speed 156Kbps 625Kbps 2.5Mbps 5Mbps 10Mbps (Note) Maximum overall cable length 1200m 900m 400m
.35 3.6.1 .35 3.6.2 .37 3.6.3 .39 3.7 .42 3.7.1 .42 3.7.2 .45 3.7.3 .46 3.7.4 .47 3.7.5 .50 3.7.6 .53 3.8 .56 3.8.1 1 .56 3.8.2 1 .57 3.8.3 2 .59 3.8.4 2 .60 3 1 3CC-Link 3 CC-Link 3.1 CC-Link DC5V CC-Link Ver.1.10 10M/5M/2.5M/625K/156Kbps NRZI CC-Link BUS(EIA RS-485) CRC(X16X12X51) CC-Link Ver.1.10() HDLC 164 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps () 1200m 900m 400m
Encoding system MRZI Transmission path format Bus format (conforming to EIA RS485) CC-Link Error control system CRC (X16+X12+X5+1) Connection cable CC-Link Ver.1.10-compliant cable (Shielded 3-core twisted pair cable) Transmission format Conforming to HDLC Remote station number 1 to 64 Communication speed 156Kbps 625Kbps 2.5Mbps 5Mbps 10Mbps (Note) Maximum overall cable length 1200m 900m 400m
Encoding system MRZI Transmission path format Bus format (conforming to EIA RS485) CC-Link Error control system CRC (X16+X12+X5+1) Connection cable CC-Link Ver.1.10-compliant cable (Shielded 3-core twisted pair cable) Transmission format Conforming to HDLC Remote station number 1 to 64 Communication speed 156Kbps 625Kbps 2.5Mbps 5Mbps 10Mbps (Note) Maximum overall cable length 1200m 900m 400m
Encoding system MRZI Transmission path format Bus format (conforming to EIA RS485) CC-Link Error control system CRC (X16+X12+X5+1) Connection cable CC-Link Ver.1.10-compliant cable (Shielded 3-core twisted pair cable) Transmission format Conforming to HDLC Remote station number 1 to 64 Communication speed 156Kbps 625Kbps 2.5Mbps 5Mbps 10Mbps (Note) Maximum overall cable length 1200m 900m 400m
Baud rat e M axi m um ext ended cabl e l engt h 10M bps 100m 5M bps 160m 2. 5M bps 400m 625Kbps 900m 156Kbps 1200m I n t he abovem ent i oned, al l equi pm ent and cabl es are goods f or Ver. 1. 10. Pl ease i nqui re of t he CCLi nk soci et y about ot her connect i on and det ai l s.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, SLIDER, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 10.03103 lb, ModelStroke [mm]Product weight [kg]Step motorServo motorLEY32D302.49?
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, LC, 32MM LE ELECTRIC ACTUATOR, 14.38516 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller: Step Data Input Type, PNP, I/O Cable Length: -, Communication Plug Connector: -, Controller Option:
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller: Step Data Input Type, PNP, I/O Cable Length: -, Communication Plug Connector: -, Controller Option:
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller: Step Data Input Type, PNP, I/O Cable Length: -, Communication Plug Connector: -, Controller Option: -
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller: Step Data Input Type, PNP, I/O Cable Length: -, Communication Plug Connector: -, Controller Option: -
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 5, Controller: Step Data Input Type, PNP, I/O Cable Length: -, Communication Plug Connector: -, Controller Option: -
The LES series electric slide table actuator uses a compactly-integrated, recirculating linear guide for high rigidity and high precision. When the LES is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein.. Two types of built-in motors * are available. The series can be top or bottom mounted. In