SMC Corporation of America
Elite Part Number Search
Search Results "LEY32DA-500M-R16N1"

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 1.5m

Dimensions [mm] Model L A B n D E F G H Without lock With lock LEKFS25Em-100m 335.5 380.5 106 210 4 100 45 LEKFS25Em-200m 435.5 480.5 206 310 6 2 240 220 LEKFS25Em-300m 535.5 580.5 306 410 8 3 360 340 LEKFS25Em-400m 635.5 680.5 406 510 8 3 360 340 LEKFS25Em-500m 735.5 780.5 506 610 10 4 480 460 35 14 LEKFS Series Battery-less Absolute (Step Motor 24 VDC) Dimensions: In-line Motor LEKFS32E

Length 20m 33m 100m 153m 305m 500m Symbol 20 33 100 153 305 500 Tube I.D. Colors indication Color Black White Red Blue Symbol B W R BU Color Yellow Green Clear Orange Symbol Y G C YR Longer lengths available upon request 20m and 100m are stocked item. Refer to Best Pneumatics for other 21 available colors.

T0425B-500X3 Available 150m for 10, 200m for 8, 500m for 4 and 6. Contact SMC for other lengths. Suffix -X3 to the end of part number. Ex.)

TU0425B-500X3 Available 150m for 10, 200m for 8, 500m for 4 and 6. Contact SMC for other lengths. Suffix -X3 to the end of part number. Ex.) TIUB01Y-100X3 Consult SMC in case of 16. 2.4-3

Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: None, Rod End Thread: M (Male), Mounting: F (Rod Flange), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable

Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type

Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: None, Rod End Thread: Male, Mounting: Rod Flange, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller

Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for

Actuator part number Controller (Except cable specifications and actuator options) Example: Enter LER10K-2 for the LER10K-2L-R16N1. Compatible motor P Step motor (Servo/24 VDC) Option Number of step data (Points) Nil D Note) Screw mounting DIN rail mounting I/O cable length [m] 6 64 Nil 1 3 5 Without cable 1.5 3 5 Note) DIN rail is not included. Order it separately.

Electric equipment Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter LEHZ10LK2-4 for the LEHZ10LK2-4AF-R16N1.

Controller Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1. BC Blank controller Note) Compatible motor P Step motor (Servo/24 VDC) A Servo motor (24 VDC) Note) The dedicated software (LEC-BCW) is required.

Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1.

Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter [LEFS16A-400] for LEFS16A-400B-R16N1 Step motor (Servo/24 VDC) P A Servo motor (24 VDC) Note 1) Option I/O cable length [m] Nil D Note 2) Screw mounting DIN rail mounting Number of step data (Points) Nil 1 3 5 Without cable 1.5 3 5 6 64 Note 2) DIN rail

Controller Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1. BC Blank controller Note) Compatible motor P Step motor (Servo/24 VDC) A Servo motor (24 VDC) Note) The dedicated software (LEC-BCW) is required.

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32, 16), Stroke: 100mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): 6N (LECA6, Step Data Input Type, NPN), I/O Cable Length for LEC: 1 (1.5m), Controller Mounting: Screw Mounting, Communication

Size: 32, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 12; LEY32, 16, Stroke: 100mm, Motor: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 1.5m, Controller Type (LEC, JXC): LECA6, Step Data Input Type, NPN, I/O Cable Length for LEC: 1.5m, Controller Mounting: Screw Mounting, Communication Plug Connector

Read this operation manual with taking a look at the unit to facilitate your understanding. 1.2 Operation by external communication It complies with communication standard RS-232C or RS-485 and can have a cable with length up to 15m or 500m.

The transmission cable length, i.e., transmittable distance, is 500m. RS-485 enables one master computer to set and monitor operation conditions of up to 31 Thermo Electric Baths. HEBC002-WB10 This product has a communication function conforming to communication protocol RS-232C. The transmittable distance is 15m.