Digital Flow Switch for Air Digital Flow Switch for Water Series PFA Series PFA Series PFW Series PFW New New 12000l 6000l 3000l Flow rate 40l 500l Photo Flow rate Photo 200l 100l 16l 50l Photo 4l Photo 10l Size (port size)) Size (port size) Maximum Flow Rate 3000, 6000, 12000l/min The addition of the high flow rate types supports energy saving measures.
CQ-M3 x 30L x 35L x 40L x 45L x 50L x 55L CQ-M3 x 30L x 35L x 40L x 45L x 50L x 55L CQ-M5 x 30L x 35L x 40L x 45L Mounting bolt part no. CQ-M5 x 50L x 55L x 60L x 65L x 70L x 75L CQ-M5 x 35L x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L Mounting method: Mounting bolt for through-hole mounting style of CQSYB is available as an option.
Symbol 100 200 500 50 10 Rc NPT G 01 02 03 04 1/8 1/4 3/8 1/2 PFA510, 550 PFA511, 521 PFA551 Specifications PFA511 PFA521 PFA551 PFA510 PFA550 Model Measured fluid Dry air, N2 Detection type Heater type 20 to 200l/min 50 to 500l/min 10 to 100l/min 1 to 10l/min 5 to 50l/min Flow rate measurement range Operating pressure range 0 to 0.5MPa Withstand pressure 1.0MPa 3kPa (at 50l/min) 3kPa
Note IDG30, 30H, 30L IDG5, 50H, 50L IDG60, 60H, 60L, 60S IDG75, 75H, 75L, 75S IDG100, 100H, 100L, 100S 1 2 3 4 5 Body Aluminum alloy Platinum silver coating Case Stainless steel Orifice Stainless steel Holder Silencer Aluminum alloy Aluminum Resin + Copper alloy Replacement parts Part number No.
Note AM IDG30/30H/30L IDG50/50H/50L IDG60/60H/60L/60S IDG75/75H/75L/75S IDG100/100H/100L/100S q w e r t Body Aluminum alloy Platinum silver coated Misc. Case Stainless steel Orifice Stainless steel Holder Aluminum alloy Aluminum Silencer Resin + Copper alloy Replacement Parts Part no. No.
Note AM IDG30/30H/30L IDG50/50H/50L IDG60/60H/60L/60S IDG75/75H/75L/75S IDG100/100H/100L/100S q w e r t Body Aluminum alloy Platinum silver coated Misc. Case Stainless steel Orifice Stainless steel Holder Aluminum alloy Aluminum Silencer Resin + Copper alloy Replacement Parts Part no. No.
/min (0.18 to 1.77SCFM) 0.5l/min (0.02SCFM) l/min, CFM x 10-2 Instantaneous flow rate Cumulative flow rate Display units l, ft3 x 10-1 0 to 0.5MPa (0 to 72psi) 1.0MPa (145psi) 3kPa (50l/min) [0.44psi (1.77SCFM)] 0 to 9l (0 to 35,300 ft3) 0 to 50C (32 to 122F) with no condensation 5% F.S. or less 1% F.S. or less Operating pressure range Withstanding pressure Pressure loss Cumulative flow
. -45- 6 /250km /500 1. 2. 3. 2 LEY16*A 2,000km LEY25*A 2,500km LEY32A 4,000km LEY16*B 1,000km LEY25*B 1,200km LEY32B 2,000km LEY16*C 500km LEY25*C 600km LEY32C 1,000km a. b. c. d. e. f. -46- 7.5. 1. 2. (1mm ) 3. 4. N Nm LEY16 LE-D-2-1 10 0.36 LEY25 LE-D-2-2 19 0.63 LEY32 LE-D-2-3 30 1.5 5. LEY32 Nm LEY16 0.63 LEY25 1.5 LEY32 5.2 6. -47- 8.
JXC-OMU0029-A LEY32A / LEYG32A LEY32B / LEYG32B LEY32C / LEYG32C Speed [mm/s] Acceleration Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] [mm/s2] 0 24 200 12 200 6 200 1 32 300 19 300 15 300 2 40 400 23 400 20 400 3 48 500 27 500 30 500 4 56 600 32 600 40 600 5 64 700 44 700 50 700 6 80 800 54 800 60 800 7 100 900 77 900 70 900 8 150 1000 90 1000 80 1000 9 200 1200 120
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: NPN, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-300, I/O cable length / communication plug(m): 3, Controller/driver mounting method: DIN rail mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): 5, Controller/driver mounting method: DIN rail mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-30, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: DIN rail mounting type
Since the marked point is below the curve for 50l/min (ANR), the maximum rate will be about 50l/min (ANR).
Since the marked point is below the curve for 50l/min (ANR), the maximum rate will be about 50l/min (ANR).
Since the marked point is below the curve for 50l/min (ANR), the maximum rate will be about 50l/min (ANR).
SET MODE SD SG RD RS-232C COM S.STOP OUT1OUT2OUT3OUT4OUT5 AC100~240V Pulse counter M/C Flow control for each branch line For Air P.2 50l/min 10l/min 500l/min 200l/min 100l/min 12000l/min 6000l/min 3000l/min Flow rate measurement range l/min Integrated display type Remote type Output specifications Port size (Rc, NPT, G) 1/8 1/4 3/8 1/2 11/2 1 2 Switch output Analog output Accumulated pulse
[mm] Dimensions Model L A B n D E Without lock With lock 11-LEFS32l-50l 332 384 56 180 4 11-LEFS32l-100l 382 434 106 230 4 11-LEFS32l-150l 432 484 156 280 4 11-LEFS32l-200l 482 534 206 330 6 2 300 11-LEFS32l-250l 532 584 256 380 6 2 300 11-LEFS32l-300l 582 634 306 430 6 2 300 11-LEFS32l-350l 632 684 356 480 8 3 450 11-LEFS32l-400l 682 734 406 530 8 3 450 11-LEFS32l-450l 732 784 456