Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): 5, Controller/driver mounting method: DIN rail mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-30, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32C-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: DIN rail mounting type

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: None, Rod End Thread: M (Male), Mounting: D (Double Clevis), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: None, Rod End Thread: Male, Mounting: Double Clevis, Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 200mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: w/Lock, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug

Read this operation manual with taking a look at the unit to facilitate your understanding. 1.2 Operation by external communication It complies with communication standard RS-232C or RS-485 and can have a cable with length up to 15m or 500m.

The transmission cable length, i.e., transmittable distance, is 500m. RS-485 enables one master computer to set and monitor operation conditions of up to 31 Thermo Electric Baths. HEBC002-WB10 This product has a communication function conforming to communication protocol RS-232C. The transmittable distance is 15m.

The communication cable length is 500m in total. RS-485 enables one master computer to set and monitor operation conditions of up to 16 products. HED00*-W2B* (Set part No.: HED00*-W2 B *) This product has a communication function conforming to communication protocol RS-232C. The communication cable length is 15m.

E2E-X2D1-N () DC1224V(DC1030V),(P-P) () 0.8mA 1.5kHZ () 3100mA (LED) (LED) -2570() 3595%RH 1 2 3V AC1000V 1055HZ1.5mmXYZ 2h 2(50G) XYZ 10 500m/S IEC IP67(JEM IP67G ) 1)100mA 2m 2) 8-2. -19-19-19-90 -19-19-1920 - 1. 2. 3. 1. 2. 3. 4. 5. 6. 7. 1. 2. 1. 2. 1. 2. 1. 2. 3. 1. 2. 3. () 4. 5. 1. 2. 1. 2. 1. ON (ON) 1. , 2. ON 3. 60 4.

RS-485 can have a cable with length up to 500m. The content which can be communicated is as follows. 1) Setting and reading of target temperature 2) Reading of the value detected by temperature sensor 3) Reading of warning status 4) Setting and reading of off-set value For operation by communication, it is necessary to order Communication Specifications.

Name Size 1 Valve Rc1/2 2 Y-shaped strainer or filter Rc1/2 (#40) Rc1/2 (500m) 3 Flow meter 0 to 30 L/min 4 Others (Pipe, hose, etc.) I.D15more HRSE Series 3.4 PIPING 3-11 HRX-OM-R039 Chapter 3 Transport and Setting Up 3.5 Fill of circulating fluid Turn the tank lid anticlockwise to open. Supply the circulating fluid up to the H mark on the fluid level indicator.