Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O
Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 1 (1.5m)
Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC:
Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 6.12884 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Actuation typeGuide typeOperating temp. rangeOperating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 7)Standby power consumption when operating [W] Note 8)Momentary max. power consumption [W] Note 9)Controller weightType Note 10)Holding force lbf [N]Power consumption [W] Note 11)HorizontalVerticalLEY25A30, 50, 100, 150, 200250, 300
Actuation typeGuide typeOperating temp. rangeOperating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 7)Standby power consumption when operating [W] Note 8)Momentary max. power consumption [W] Note 9)Controller weightType Note 10)Holding force lbf [N]Power consumption [W] Note 11)HorizontalVerticalLEY25A30, 50, 100, 150, 200250, 300
Actuation typeGuide typeOperating temp. rangeOperating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 7)Standby power consumption when operating [W] Note 8)Momentary max. power consumption [W] Note 9)Controller weightType Note 10)Holding force lbf [N]Power consumption [W] Note 11)HorizontalVerticalLEY25A30, 50, 100, 150, 200250, 300
Actuation typeGuide typeOperating temp. rangeOperating humidity range [%RH]Motor sizeMotor output [W]Motor typeEncoderRated voltage [V]Power consumption [W] Note 7)Standby power consumption when operating [W] Note 8)Momentary max. power consumption [W] Note 9)Controller weightType Note 10)Holding force lbf [N]Power consumption [W] Note 11)HorizontalVerticalLEY25A30, 50, 100, 150, 200250, 300
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY25AB-150, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Parallel I/O Type: N (NPN), I/O Cable Length: 5m, DIN Rail: D (DIN Rail Mounting), Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: Top Mounting Type, Lead: B (16: 5mm; 25: 6mm), Stroke: 300mm
Parallel I/O Type: N (NPN), I/O Cable Length: w/o Cable, DIN Rail: D (DIN Rail Mounting), Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: Top Mounting Type, Lead: B (16: 5mm; 25: 6mm), Stroke: 300mm
Parallel I/O Type: N (NPN), I/O Cable Length: 1 (1.5m), DIN Rail: Screw Mounting, Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: Top Mounting Type, Lead: B (16: 5mm; 25: 6mm), Stroke: 300mm
Parallel I/O Type: N (NPN), I/O Cable Length: 3m, DIN Rail: D (DIN Rail Mounting), Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: Top Mounting Type, Lead: B (16: 5mm; 25: 6mm), Stroke: 300mm
Parallel I/O Type: P (PNP), I/O Cable Length: 1 (1.5m), DIN Rail: Screw Mounting, Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: Top Mounting Type, Lead: B (16: 5mm; 25: 6mm), Stroke: 300mm
Parallel I/O Type: P (PNP), I/O Cable Length: 5m, DIN Rail: Screw Mounting, Type: Rod Type, Body Size: 25, Bearing Type: None, Motor Mounting: Top Mounting Type, Lead: B (16: 5mm; 25: 6mm), Stroke: 300mm