Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECP1, PNP, Programless Type, I/O Cable Length for LEC: 5m, Controller
LEY16A / LEYG16A LEY16B / LEYG16B LEY16C / LEYG16C Speed [mm/s] Acceleration Speed [mm/s] Acceleration Speed [mm/s] Acceleration [mm/s2] [mm/s2] [mm/s2] 0 15 200 8 200 4 200 1 20 300 10 300 6 300 2 30 400 15 400 8 400 3 40 500 20 500 10 500 4 50 600 25 600 13 600 5 60 700 30 700 15 700 6 80 800 40 800 20 800 7 100 900 50 900 25 900 8 150 1000 75 1000 38 1000 9 200 1200 100 1200 50 1200 10
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 200mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Body Bottom Tapped, Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller: PNP Controller, I/O Cable Length: 5m, Communication Plug Connector: None, Controller Mounting: DIN
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 200mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 200mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 5m, Controller
Rough guide for distance from conductor to prevent malfunction (10,000A: 30cm or more).
Make the input and output cables as short as possible, and also make the grounding cable as long as possible (about 30cm) to minimize leakage currents.
AF AR IR VEX ALD900 Mounting/Adjustment AW Caution qProvide about 30cm of space above and below the D.P. Lube or the D.P.
Make the input and output cables as short as possible, and also make the grounding cable as long as possible (about 30cm) to minimize leakage currents.
Make the input and output cables as short as possible, and also make the grounding cable as long as possible (about 30cm) to minimize leakage currents.
(L) W E L d 13 25 13 13.7 (1) ACPWM 30cm 10{IglIgnIgaK(Ig2Igm)}[mA] (14.1) K NV NV-SP NV-SW NV-CP NV-CW NV-HW M 1 Ig1 Iga Ig2 Igm Ign BV-C1 NFB 3 NV-L Igl (13.4 ) Ig2 (13.4 ) Ign (FR-BIF-(H)()4.4mA) Iga(13.5 ) Igm((13.4 ) 120 100 80 60 40 [mA] [mA] 20 0 2 100 5.5 14 38 8 3.5 22 60 150 30 80 [mm] [mm2] a. 200V 13.4 CV1km(lg1lg2) 13 26 13 13.4 (Igm) [kW] [mA] 0.051 0.1 13.5 (Iga) [kW
Make the input and output cables as short as possible, and also make the grounding cable as long as possible (about 30cm) to minimize leakage currents.
(L) W E L d 11 30 11 11.8 (1) ACPWM 30cm 10{IglIgnIgaK(Ig2Igm)}[mA](11.1) K NV M NV-SP NV-SW NV-CP NV-CW NV-HW 1 Ig1 Iga Ig2 Igm Ign BV-C1 NFB 3 NV-L Igl (11.3) Ig2 (11.3) Ign (FR-BIF-(H) ()4.4mA) Iga(11.6) Igm (11.5) 120 120 100 100 80 80 60 60 40 40 [mA] [mA] [mA] [mA] 20 20 0 2 0 2 100 5.5 14 38 14 100 5.5 38 8 3.5 22 60 150 8 3.5 22 60 150 30 80 30 80 2] [mm 2] [mm [mm2] [mm2]
Make the input and output cables as short as possible, and also make the grounding cable as long as possible (about 30cm) to minimize leakage currents.
(L) W E L d 11 25 11. 11.9 (1) ACPWM 30cm 10 {Ig1 + Ign + Iga + K (Ig2 + Igm)} [mA] (11.1) K NV M NV-SP NV-SW NV-CP NV-CW NV-HW 1 Ig1 Iga Ig2 Igm Ign BV-C1 NFB 3 NV-L Ig1: (11.5) Ig2: (11.5) Ign: (FR-BIF14.4mA) Iga: (11.3) Igm: (11.2) 120 10 0 [mA] 80 60 40 20 0 2 5.5 14 38 100 3.5 8 22 60 15 0 80 30 [mm] 11.7 CV1km(lg1lg2) 11 26 11. 11.2 (Igm) [W] [mA] 50750 0.1 11.3 (Iga
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, GC, 16MM LE ELECTRIC ACTUATOR, 3.88957 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 16, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included)