Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-100, I/O cable length / communication plug(m): 3, Controller/driver mounting method: Screw mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Servo motor (24 V DC), Step data (points): 64, Actuator/cable type: LEY16AA-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

Dimensions [mm] Model L A B n D E F G H Without lock With lock LEKFS25Em-100m 335.5 380.5 106 210 4 100 45 LEKFS25Em-200m 435.5 480.5 206 310 6 2 240 220 LEKFS25Em-300m 535.5 580.5 306 410 8 3 360 340 LEKFS25Em-400m 635.5 680.5 406 510 8 3 360 340 LEKFS25Em-500m 735.5 780.5 506 610 10 4 480 460 35 14 LEKFS Series Battery-less Absolute (Step Motor 24 VDC) Dimensions: In-line Motor LEKFS32E

(between lead wire and case) Operating time .1.2ms Ambient temperature . 10 to 60C Impact resistance . 300m/s D-A90(V) Contact protection box OUT() Brown [Red] Reed switch CD-P11 OUT( ) Blue [Black] CD-P12 Leakage current . 0 Enclosure . IEC529 standard IP67 (JISC0920) watertight Note) Refer to page 12 for lead wire lengths.

SMC Electronic Switch Series Variations Model Selection Table Self-contained Style ZSE1 ISE1 ZSE2 ISE2 PS1000 PS1100 ZSP1 GS40 ISA ZSE3 ISE3 Model General pneumatic Fluid Calibration method Trimmer calibration 0.1 to 0.45MPa 0.1 to 0.4MPa 0 to 0.98 MPa 101 to 20kPa 0.1 to 0.2MPa (Detection zone 10 to 300m) 0 to 100kPa 0 to 1MPa 101 to 0kPa 0 to 98kPa 0 to 0.98MPa 101 to 0kPa Calibration pressure

When excessive impact (300m/s2 or more) is applied to a reed switch during operation, the contact point will malfunction and generate or cut off a signal momentarily (1ms or less). Consult SMC regarding the need to use a solid state switch depending upon the environment. 7. Do not use in an area where surges are generated.

(between lead wire and case) Operating time 1.2ms Ambient temperature 10 to 60C (14 to 140F) Impact resistance 300m/s Leakage current None Enclosure IEC529 standard IP67, watertight (JISC0920) For a lead wire length of 3m, "L" is shown at the end of the part number.

Actuator part number Controller (Except cable specifications and actuator options) Example: Enter LER10K-2 for the LER10K-2L-R16N1. Compatible motor P Step motor (Servo/24 VDC) Option Number of step data (Points) Nil D Note) Screw mounting DIN rail mounting I/O cable length [m] 6 64 Nil 1 3 5 Without cable 1.5 3 5 Note) DIN rail is not included. Order it separately.

Electric equipment Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter LEHZ10LK2-4 for the LEHZ10LK2-4AF-R16N1.

Controller Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1. BC Blank controller Note) Compatible motor P Step motor (Servo/24 VDC) A Servo motor (24 VDC) Note) The dedicated software (LEC-BCW) is required.

Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1.

Series LECP6 Series LECA6 Controller Actuator part number Compatible motor (Except cable specifications and actuator options) Example: Enter [LEFS16A-400] for LEFS16A-400B-R16N1 Step motor (Servo/24 VDC) P A Servo motor (24 VDC) Note 1) Option I/O cable length [m] Nil D Note 2) Screw mounting DIN rail mounting Number of step data (Points) Nil 1 3 5 Without cable 1.5 3 5 6 64 Note 2) DIN rail

Controller Actuator part number Part number except cable specifications and actuator options Example: Enter LEFS16A-400 for the LEFS16A-400B-R16N1. BC Blank controller Note) Compatible motor P Step motor (Servo/24 VDC) A Servo motor (24 VDC) Note) The dedicated software (LEC-BCW) is required.

When excessive impact (300m/s2 or more) is applied to a reed auto switch during operation, the contacts may malfunction and generate or cut off a signal momentarily (1ms or less). Please consult with SMC if a solid state auto switch can be used according to the environment. 16 - 6. Do not use in an area where surges are generated.

When excessive impact (300m/s2 or more) is applied to a reed auto switch during operation, the contacts may malfunction and generate or cut off a signal momentarily (1ms or less). Please consult with SMC if a solid state auto switch can be used according to the environment. 6. Do not use in an area where surges are generated.

When excessive impact (300m/s2 or more) is applied to a reed auto switch during operation, the contacts may malfunction and generate or cut off a signal momentarily (1ms or less). Please consult with SMC if a solid state auto switch can be used according to the environment. Do not use in an area where surges are generated.

Do not drop, bump or apply excessive impacts (300m/s or more for reed switches and 1000m/s or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires.

Heavy duty oil resistant vinyl cord, 3.4, 0.2mm, 2 wire (Brown, Blue [Red, Black]), 3 wire (Brown, Black, Blue [Red, White, Black]), 0.5m (D-Z73 only 2.7, 0.18mm, 2 wire) Impact resistance . 300m/S {30.6G} Insulation resistance . 50M or more at 500VDC (between lead wire and case) Withstand voltage .1500VAC for 1min.

(between lead wire and case) Operation time 1.2ms Ambient temperature 10 to 60C Impact resistance 300m/s {30.6G} Leakage current 0 Enclosure IEC529 standard IP67 (JIS0920) watertight For a lead wire length of 3m, "L" is added to the end of the part number.

When excessive impact (300m/s or more) is applied to a reed switch during operation, the contact point may malfunction and generate or cut off a signal momentarily (1ms or less). Consult with SMC regarding the need to use a solid state switch depending on the environment. 7. Do not use in an area where surges are generated.