]) (2000 [mm/s2]) (3000 [mm/s2]) Note 2) Work load [lb] Horizontal Vertical Actuator specifications Electric specifications Lock unit Pushing force [N] Note 3) 4) 5) Speed [mm/s] Note 5) Max. acceleration/deceleration [mm/s2] Pushing speed [mm/s] Note 6) 50 or less 30 or less 35 or less Positioning repeatability [mm] 0.02 Screw lead [mm] Impact/Vibration resistance [m/s2] Note 7) 10 5 2.5

CQ2 series Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A B + Stroke S2 L B + Stroke S1 L B + Stroke S2 L L B + Stroke S1 A + Stroke (S1 + S2) A + Stroke (S1 + S2) Note) In the case of bore sizes 12 to 25 with auto switch, port directions are different.

Maximum acceleration: 2000mm/s2 Positioning distance (mm) 1 1000 500 100 10 10 0.5 100.5 50.5 10.5 1.5 100 0.5 10.5 5.5 1.5 0.6 Speed (mm/s) 500 0.5 2.7 1.7 0.9 0.6 1000 0.5 1.9 1.4 0.9 0.6 A B C D Values will vary slightly depending on the operating conditions.

) Standard Load (4.90 m/s2) 4.0 4.0 300 mm/s LJ1 LJ1 300 mm/s 3.5 3.5 LG1 LG1 400 400 500 LTF LTF 3.0 3.0 LC1 LC1 600 500 2.5 2.5 LC7 LC7 800 Tact time (sec) Tact time (sec) 600 1000 LC8 LC8 2.0 2.0 800 LXF LXF 1.5 1.5 LXP LXP LXS LXS 1000 1.0 1.0 1200 1600 2000 LC6m LC6m 0.5 0.5 LZm LZm LC3F2 LC3F2 0 0 500 1000 0 0 500 1000 Xm Xm Stroke (mm) Stroke (mm) D-m D-m Medium Load (9.80 m/s2) Light

Lead wire length 2000 mm Cover Concave Pin Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lever DC indicator Socket Part no.

Example) VQ1140-5L-C6-A A port, Plug 2-4-61 Body Ported Series VQ0/1000/2000 Manifold Option Parts Double check block (Separated type): For VQ0/1000 VQ1000-FPGIt is used on the outlet side piping to keep the cylinder in the intermediate position for a long time.

1 min. between external terminal and case Insulation resistance 50M or more (500 VDC Mega) between external terminal and case 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller. 4.9 m/s2 Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance Noise resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Weight Note 3) 410 g 470 g

COM. 13 (+) 13 () Voltage limit V, 1 minute, AC 1000 Positive common Negative common Insulation resistance M/km, 20C 5 or more Note) When using a valve with no polarity, either positive common or negative common can be used. Note) The minimum bending radius of the D-sub connector cable is 20 mm.

to 300 to 300 to 300 LJ1H202PA 8 50 to 500 124 112 106 LJ1H202NA 12 54 to 500 LJ1H303SE 126 114 22 64 to 500 to 500 to 500 LJ1H202PC 10 52 to 1000 to 740 to 930 to 600 to 500 145 124 112 106 LJ1H202NC 14 56 to 740 to 930 to 600 to 500 to 1000 LJ1H303PD 18 60 to 1000 to 1000 to 700 to 500 to 1000 126 114 108 LJ1H303ND 20 62 to 1000 to 1000 to 700 to 500 to 1000 LJ1H102PH-K 24 66 to 400

) (1000) (1000) (1000) MY1MW20 MY1MW20 30 30 (1000) (900) (1000) (900) (1000) (900) (1000) (900) Caution MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 MY1CW16 (900) (900) (900) (900) 20 20 1.

) Vibration resistance 98 m/s2 in each X, Y, Z direction, 3 times (De-energized) Impact resistance Standard CE marking, UL (CSA) Tie-rod 2 pcs.

Maximum acceleration: 2000mm/s2 Positioning distance (mm) 1 1000 500 100 10 10 0.5 100.5 50.5 10.5 1.5 100 0.5 10.5 5.5 1.5 0.6 Speed (mm/s) 500 0.5 2.7 1.7 0.9 0.6 1000 0.5 1.9 1.4 0.9 0.6 A B C D Values will vary slightly depending on the operating conditions.

Maximum acceleration: 2000 mm/s2 1 Positioning distance (mm) 10 100 500 1000 0.5 10 1.5 10.5 50.5 100.5 0.5 100 0.6 1.5 5.5 10.5 Speed (mm/s) 0.5 500 0.6 0.9 1.7 2.7 0.5 1000 0.6 0.9 1.4 1.9 A B C D Values will vary slightly depending on the operating conditions.

Cylinder Speed Chart Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Stroke 1000 mm Average speed (mm/s) System 50 63 80 100 125 140 160 180 200 250 300 1000 Perpendicular, upward actuation 900 800 700 600 500 400 300 200 100 VK Horizontal actuation A VZ VF 0 1000 VFR 900 800 700 600 500 400 300 200 100 0 VP4 Courtesy of Steven

]) 20 40 60 30 45 60 Horizontal (2000 [mm/s2]) 30 60 70 40 60 80 Work load [kg] Note 2) For LECPA (3000 [mm/s2]) 12 30 30 20 40 40 (2000 [mm/s2]) 18 50 50 30 60 60 Actuator specifications Vertical Note 15) (3000 [mm/s2]) 7 15 29 10 21 42 Pushing force [N] Note 3) Note 4) Note 5) 63 to 122 126 to 238 232 to 452 80 to 189 156 to 370 296 to 707 Speed [mm/s] Note 5) 18 to 400 9 to 200 5 to 100

Auto Switches Common Specifications Type Reed auto switch Solid state auto switch Leakage current 3-wire: 100 A or less, 2-wire: 0.8 mA or less None Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 (4) 300 m/s2 Insulation resistance 50 M or more at 500 VDC Mega (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between

S3 U0 U1 U2 U3 S0 S1 S2 S3 U0 U1 U2 U3 F F U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 S0 S1 S2 S3 S0 S1 S2 S3 Without cable Without cable Without cable (2) (2) (2) (2) Kit Kit Kit Kit Kit Kit With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable

, 1200, 1500, 900, 1000, 1200, 1500, Stroke [mm] Note1) 900, 1000 1800, 2000 1800, 2000 1 10 19 LECP6/LECP1/LECPMJ/JXC91 Work load [kg] note2) Horizontal 1 5 14 LECPA Actuator specification 48 to 1100 48 to 1400 48 to 1500 Note2)Speed [mm/s] 3,000 Max.acceleration/deceleration [mm/s2] 0.08 Positioning repeeatability [mm] 0.1 or less Lost motion[mm] note3) Equivalent lead [mm] 48 48 48 50

For details, refer to SMC Best Pneumatics catalog vol. 8, page 8-30-31/8-30-32. 18 Series CY3 Auto Switch Specifications Auto Switch Common Specifications Solid state switch Reed switch Type Leakage current 3-wire: 100 A or less 2-wire: 0.8 mA or less None Operating time 1 ms or less 1.2 ms 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 Mega VDC (between lead wire and case) Insulation

VAC for 1 min. between external terminal and case Insulation resistance 50 M (500 VDC) between external terminal and case 4.9 m/s2 10 to 500 Hz at whichever is smaller: 1.5 mm amplitude or 98 m/s2 acceleration in X, Y, Z directions for 2 hrs. each Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance Noise resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns