.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Acceleration Stroke Cushion seal RHC MK(2) 15 m/s2 5 m/s2 (REB) (REA) RS Q G High precision guide type: REAHT (Double axis) High precision guide type: REBHT (Double axis) RS H A REB REA RZQ High precision guide type: REAH (Single axis) High precision
(STO switch) S2: Start switch (STO release switch) S3: On switch S4: Off switch KM1: Magnetic contactor K3: Safety relay EMG: Emergency stop switch CN3 EM1 or EM2 M Servo motor Note.
4.56 4.81 5.06 5.31 5.56 5.81 6.06 6.31 6.56 6.81 7.06 7.31 T6 3.04 3.29 3.54 3.79 4.04 4.29 4.54 4.79 5.04 5.29 5.54 5.79 6.04 6.29 6.54 6.79 7.04 7.29 Additional weight for lock(kg) S2:0.2/S6:0.3/T6:0.3 Model LEFB32 Stroke [mm] 300 400 500 600 700 800 900 1000 (1100) 1200 (1300) (1400) 1500 (1600) (1700) (1800) (1900) 2000 2500 S3 4.90 5.25 5.60 5.95 6.30 6.65 7.00 7.35 7.70 8.05 8.40
One-touch fitting symbol Applicable tube O.D. mm Bar length mm Single end piping Double ends piping 06 6 340 to 640 340 to 1300 08 8 340 to 1300 340 to 2500 10 10 340 to 2500 340 to 2500 06 6 340 to 1300 340 to 2500 08 8 340 to 2500 340 to 2500 10 10 340 to 2500 340 to 2500 06 6 340 to 2500 340 to 2500 08 8 340 to 2500 340 to 2500 10 10 340 to 2500 340 to 2500 High speed static neutralization
Move M Spee Pushing Sp mm/s mm mm/s2 mm/s2 % % mm/s % mm mm mm 0 Absolute 500 100.00 2500 2500 0 0 0 100 0.00 0.00 1.00 1 Absolute 500 0.00 2500 2500 0 0 0 100 0.00 0.00 1.00 When the relative position is required, set Relative Absolute: Distance from the origin position. / General setting method Relative: Feed from the current position. / This is used when simplified data. b < Speed> Transfer
Lubrication Not required Mounting orientation Unrestricted 300/50 Note 2) Impact/Vibration resistance (m/s2) Note 1) In case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation.
With 2 pcs. 1660 to 2380 With 2 pcs. 2440 to 2500 With 3 pcs.
Ambient & Fluid Temperature -10 ~ 50C A Clean Room version is available to specified Lubrication Not Required order please contact your local SMC Sales Office Manual Override Non-Locking Push Type Shock Resistance/Vibration Resistance 150 / 30m/s2 for further information. Mounting Orientation Free The VQD1000 is used either on a Single SubEnclosure Dust Proof base or Manifold Mounted.
Electronic gear numerator *3 PA06 1 32768 Electronic gear denominator *3 PA07 1 2500 1500 750 3000 2000 1000 3750 2500 1250 Feel length multiplication (STM) (Multiplier) PA05 0 0(Less than stroke 1000)/ 0001(Stroke 1000 or more) Home position return type PC02 0 3Stopper type Home position return direction PC03 0001 1 (Motor side) Home position return Speed (rpm) PC04 500 90 150 300 75 113
Electronic gear numerator *3 PA06 1 32768 Electronic gear denominator *3 PA07 1 2500 1500 750 3000 2000 1000 3750 2500 1250 Feel length multiplication (STM) (Multiplier) PA05 0 0(Less than stroke 1000)/ 0001(Stroke 1000 or more) Home position return type PC02 0 3Stopper type Home position return direction PC03 0001 1 (Motor side) Home position return Speed (rpm) PC04 500 90 150 300 75 113
: 10 mm/s2 1.0 Cycle time [s] Cycle time [s] 1.0 0.5 0.5 Acceleration/Deceleration: 20 mm/s2 Acceleration/Deceleration: 20 mm/s2 0.0 0.0 0 2000 500 1000 1500 0 3000 500 1000 1500 2000 2500 Stroke [mm] Stroke [mm] Maximum work load/acceleration/deceleration graph Maximum speed/acceleration/deceleration values graph for each stroke 3 Model Selection Series LEJ Work LoadAcceleration/Deceleration
SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Impact/Vibration resistance (m/s2) 150/50 Note) Manifold Possible Use dry air (Dew point: 20C or less). If using a lubricant, be sure to use a lubricant for low temperatures.
Do not drop, bump or apply excessive impact (1,000 m/s2) when handling. Even if the switch body is not damaged, the switch may suffer internal damage that will lead to malfunction. 2. Hold the product from the body side when handling. The tensile strength of the power cord is 49 N, and pulling it with a greater force can cause failure. 3.
Mounting orientation Note 2) 150/30 IP67 (Based on IEC60529) Impact/Vibration resistance Note 2) (m/s2) Enclosure Coil rated voltage (DC) Allowable voltage fluctuation (V) 24, 12 V 10% of rated voltage Note 3) Standard 0.35 (With indicator light: 0.4) 0.9 (With indicator light: 0.95) High pressure type, Quick response type Power consumption (W) Standard: 0.1 Note 4) (With indicator light
temperature [C] HRR018-A-10 -20, HRR018-W-10 -20 [50 Hz] [60 Hz] 2500 2500 25C 25C 2000 2000 Cooling capacity [W] Cooling capacity [W] 32C 1500 1500 32C 40C 1000 1000 40C 500 500 Ambient temperature or facility water temperature Ambient temperature or facility water temperature Ambient temperature or facility water temperature Ambient temperature or facility water temperature 0 0 0 10 20
Unrestricted 300/50 m/s2 VZ Fluid Ambient and fluid temperature Response time (at the pressure of 0.5 MPa)(1) VF Manual override Lubrication Mounting orientation Impact/Vibration resistance(2) VFR VP4 Enclosure Note 1) Based on dynamic performance test, JIS B 8375-1981.
App. 33 APPENDIX Recommended Value of acceleration time constant of Point table No.1 [LEJ] LEJS100 Series Lead symbol H A B Lead 50 25 10 Point table No.1 Initial value Recommended value Home position return 0 2500 1250 500 acceleration time constant (msec) *5 Different from the initial value. 2500 for LEJ100 H Lead 2500 2500 *5.
Note 5) Dust-tight/Water-jet-proof (IP65) is not available with interface regulator. 00 2500 2000 1500 1000 500 3000 Flow rate [L/min (ANR)] ARBQ5000-00-P (PRA) 0.6 0.7 Outlet pressure [MPa] 0.5 0.4 0.3 How to Order 0.2 Solenoid valve Interface regulator Regulating port 0.1 ARBQ5000-00-A-1 A 00 2500 2000 1500 1000 500 3000 VQ5l0l (Plug-in type) ARBQ5000-00-B-1 B Flow rate [L/min (ANR)] ARBQ5000
SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.