Item Display Content Setting of connection product [4L] 4 L range [16L] 16 L range [40L] 40 L range [PFW] is selected [100L] 100 L range [250L] 250 L range [10L] 10 L range [rAnG] [50L] 50 L range Selection of flow range [100L] 100 L range [PFA] is selected [200L] 200 L range [500L] 500 L range [4L] 4 L range [PFd] is selected [16L] 16 L range [40L] 40 L range Press the SET button to set.
Humidity:30 to 70%,Altitude: Less than 3000m Circulating fluid*3 Tap water, 15% ethylene glycol aqueous solution Operating temperature range1 5 to 35 Cooling capacity (50/60Hz) 4 W 4600/ 5100 4800/ 5800 Heating capacity (50/60Hz) 5 W 1000/ 1200 1100/ 1200 Temperature stability 6 0.1 7 MPa 0.34(at 15L/min)/ 0.34(at 23L/min) Pump capacity (50/60Hz) Pump capacity of option T1 7 MPa 0.35(at 16L
Hexagon socket head cap screw (M3 x 0.5 x 16l) 2 pcs.
MHC2-16l Note) When signal acting type is used, one side port is bleed port and adjusting needle for finger speed is not attached. When auto switch is used, through hole mounting type is not available.
Note D-F7l, J79 D-F7lV D-J79C D-F7lW, J79W D-F7lWV D-F7BAL D-F7lF D-F7NTL IAuto switch mounting screw (M3 X 0.5 X 8l) ISquare nut 20/25 BQ-1 D-A7, A8 D-A73C, A80C D-A7lH, A80H D-A79W IAuto switch mounting screw (M3 X 0.5 X 10l) IAuto switch spacer IAuto switch mounting nut 32/40 50/63 BQ-2 ISwitch mounting bracket IAuto switch mounting nut ICross-recessed panhead small screw (M3 X 0.5 X 16l
Hexagon socket head cap screw (M3 x 0.5 x 16l) 2 pcs.
Hexagon socket head cap screw (M3 x 0.5 x 16l) 2 pcs.
AB TG 0.2 E TR AO AU AH AT R2 Screw size R2 TG/2 32 L5032 7 32.5 48 32 10 24 32 4.5 15 M6 x 16L 40 L5040 10 38 55 36 11 28 36 4.5 17.5 M6 x 16L 50 L5050 10 46.5 68 45 12 32 45 5.5 20 M8 x 20L 63 L5063 10 56.5 80 50 12 32 50 5.5 22.5 M8 x 20L 80 L5080 12 72 100 63 14 41 63 6.5 22.5 M10 x 20L 100 L5100 14.5 89 120 75 16 41 71 6.5 27.5 M10 x 20L AH AT AB E TR AU AO * Supplied with 4 mounting
Hexagon socket head cap screw (M3 x 0.5 x 16l) 2 pcs.
AB TG 0.2 E TR AO AU AH AT R2 Screw size R2 TG/2 32 L5032 7 32.5 48 32 10 24 32 4.5 15 M6 x 16L 40 L5040 10 38 55 36 11 28 36 4.5 17.5 M6 x 16L 50 L5050 10 46.5 68 45 12 32 45 5.5 20 M8 x 20L 63 L5063 10 56.5 80 50 12 32 50 5.5 22.5 M8 x 20L 80 L5080 12 72 100 63 14 41 63 6.5 22.5 M10 x 20L 100 L5100 14.5 89 120 75 16 41 71 6.5 27.5 M10 x 20L 125 L5125 16 110 Max. 157 90 Max. 25 45 90 8 30
/Symmetric Type 106 Air Slide Table Series MXQ Dimensions MXQ 16L/Symmetric Type 107 Series MXQ Air Slide Table Dimensions MXQ 20 108 Air Slide Table Series MXQ Dimensions MXQ 20 109 Series MXQ Air Slide Table Dimensions MXQ 20L/Symmetric Type 110 Air Slide Table Series MXQ Dimensions MXQ 20L/Symmetric Type 111 Series MXQ Air Slide Table Dimensions MXQ 25 112 Air Slide Table Series
CHQ CHK CHN Mounting correctly Mounting incorrectly CHM CHM CHS
AB AH AO AT AU E R2 TG 0.2 TR Screw size R2 TG/2 32 L5032 7 32 10 4.5 24 48 15 32.5 32 M6 x 16L 40 L5040 10 36 11 4.5 28 55 17.5 38 36 M6 x 16L 50 L5050 10 45 12 5.5 32 68 20 46.5 45 M8 x 20L 63 L5063 10 50 12 5.5 32 80 22.5 56.5 50 M8 x 20L 80 L5080 12 63 14 6.5 41 100 22.5 72 63 M10 x 20L 100 L5100 14.5 71 16 6.5 41 120 27.5 89 75 M10 x 20L AH AT AB E TR AU AO * Supplied with 4 mounting
(M3 x 0.5 x 10l) BQ-2 Switch spacer MI W S Switch mounting nut Switch mounting bracket CEP1 Switch mounting nut 40, 50 63 Round head Phillips BQP1-050 D-P5DWL screw (M3 x 0.5 x 16l) CE1 Hexagon socket head cap bolt (M3 x 0.5 x 14l) Mounting screws set made of stainless steel The set of stainless steel mounting screws (with nuts) described below is available and can be used depending
(M3 x 0.5 x 10l) BQ-2 Switch spacer MI W S Switch mounting nut Switch mounting bracket CEP1 Switch mounting nut 40, 50 63 Round head Phillips BQP1-050 D-P5DWL screw (M3 x 0.5 x 16l) CE1 Hexagon socket head cap bolt (M3 x 0.5 x 14l) Mounting screws set made of stainless steel The set of stainless steel mounting screws (with nuts) described below is available and can be used depending
Hexagon socket head cap screw (M3 x 0.5 x 16l) 2 pcs.
From this point, air consumption is approx. 16L/min[ANR]. Caution -The graph of flow-rate characteristics is in the condition of no piping for suction and discharge. It may not be possible to obtain the discharge in the graph depending on the piping conditions. In air operated type, the discharge is greatly affected by the piping conditions of pilot air.
However, the Flow rate display of HRL is up to 16L/min. Fig. 8-12 Pump capacity(HRL100/200/300-A-20CH2) Documents HRL Series 8-10 HRX-OM-Y098 Chapter 8 Documents 8.6 Types of Hazard Labels To ensure the safety of the operators, potential hazards are classified and marked with warning labels. Read this section before starting any work on the product.
However, the Flow rate display of HRL is up to 16L/min.
90 RH ) 28 42 56.4 (DC24V) A/B 800 / [V] DC2410% [W] 8) 23 40 50 [W] 9) 16 15 48 [W] 10) 43 48 104 11) [N] 20 39 78 78 157 294 108 216 421 [W] 12) 3.6 5 5 [V] DC2410% LEYG 16M _ LEYG 25M _ LEYG 32M _ [mm] 30 50 100 150 200 30 50 100 150 200 250 300 30 50 100 150 200 250 300 (kg) 0.83 0.97 1.20 1.49 1.66 1.67 1.86 2.18 2.60 2.94 3.28 3.54 2.91 3.17 3.72 4.28 4.95 5.44 5.88 LEYG 16L