Note IDG1 IDG5, 5H IDG10, 10H IDG20, 20H IDG3, 3H Body Brass Aluminum alloy 1 Platinum silver coated (IDG1 is electroless nickel plated.) Female connector Brass 2 Electroless nickel plated Strainer Brass 3 Case 4 Resin Orifice Resin Stainless steel 5 Silencer Brass 6 Replacement Parts Part no. No.
Range Setting Enabled Section Option Monitor 1 Selection 0H Motor rotating speed [10H/overspeed detection position] 0001H Speed reference [10H/overspeed detection position] 0002H Torque [10H/max. torque] 0003H Position error (lower 32 bits) [reference unit] 0004H Position error (upper 32 bits) [reference unit] 0005H System reserved 0006H System reserved 000AH Encoder count (lower 32 bits
Instance common service Service code Description 0Eh Get_Attribute_Single 10h Set_Attribute_Single 8. SMC SI Object (Class ID: 64h) 8-1. Class attribute ID Access rule Description Value 8-2. Class common service Service code Service name 8-3.
Output values for: HART Uo(Voc) = 3.53V, Io(Isc) = 12.6mA, Po = 11.1 mW, Co(Ca) = 10nF, Lo(La) = 10H. R FOUNDATION fieldbus and Profibus Uo(Voc) = 5.0V, Io(Isc) = 17.8mA, Po = 22.2mW, Co(Ca) = 10nF, Lo(La) = 10H.
PD22 *DI10H Input device selection 10H Any input device can be assigned to the CN1-45 pin. _ _ x x Torque control mode Device selection Refer to table 5.10 in [Pr. PD03] for settings. 23h x x _ _ For manufacturer setting 2Bh PD23 *DO1 Output device selection 1 _ _ x x Device selection 04h Any output device can be assigned to the CN1-22 pin.
Note IDG1 IDG5, 5H IDG10, 10H IDG20, 20H IDG3, 3H Body Brass Aluminum alloy 1 Platinum silver coated (IDG1 is electroless nickel plated.) Female connector Brass 2 Electroless nickel plated Strainer Brass 3 Case 4 Resin Orifice Resin Stainless steel 5 Silencer Bronze 6 Replacement Parts Part no. IDG1 IDG3H IDG5 IDG5H IDG10 IDG10H IDG20 IDG20H No.
71h Get/Set Monitoring short circuit at Output BOOL 0=Disable 1=Enable 01h to 40h 7Bh Get/Set Restart after short circuit BOOL 0=Manual 1=Auto SI Unit object (Class: 6Ch) [DeviceNetTM extended object library 1] Instance Attribute Access Name Type Value 71h Get/Set Monitor short circuit at Output BOOL 0=Disable 1=Enable 7Bh Get/Set Restart after short circuit BOOL 0=Manual 1=Auto 01h to 10h
Occupied byte ID number Unit Unit part number Input Output Siemens IEC61158 EX600-SPRA (32 outputs) 0 4 32DO 23h EX600-SPRA (24 outputs) 0 3 24DO 22h SI unit EX600-SPRA (16 outputs) 0 2 16DO 21h EX600-SPRA (8 outputs) 0 1 8DO 20h EX600-DXB (8 inputs) 1 0 8DI 10h EX600-DXC (8 inputs) 1 0 8DI 10h EX600-DXC1 (8 inputs) 1 0 8DI 10h (with open circuit detection) Digital input unit EX600-DXD (16
. -67No.EX-OMN0027CN-D (1)[Configuration table][Properties DP Slave] (2)[Parameter Assignment] (3)[Value][OK] (4)PLC (2) (3) (1) Siemens AG PLC STEP7 -68No.EX-OMN0027CN-D EX600 byte Siemens IEC61158 EX600-SPRA (32 ) 0 4 32DO 23h EX600-SPRA (24 ) 0 3 24DO 22h SI EX600-SPRA (16 ) 0 2 16DO 21h EX600-SPR (8 ) 0 1 8DO 20h EX600-DXB (8 ) 1 0 8DI 10h EX600-DXC (8 ) 1 0 8DI 10h EX600-DXC1 (8
Male thread nozzle 02 03 N02 N03 F02 F03 11 12 H06 H08 H10 H07 H09 H11 Rc1/4 Rc3/8 NPT1/4 NPT3/8 G1/4 G3/8 KK4P-02MS KK130P-02MS KQ2H06-02S KQ2H08-02S KQ2H10-02S KQ2H07-35S KQ2H09-35S KQ2H11-35S Threaded Thread size High efficiency nozzle S coupler plug Model no. of coupler used Low noise nozzle with male thread Metric size one-touch fitting Model no. of fitting used Extension nozzle Inch
Male thread nozzle 02 03 N02 N03 F02 F03 11 12 H06 H08 H10 H07 H09 H11 Rc1/4 Rc3/8 NPT1/4 NPT3/8 G1/4 G3/8 KK4P-02MS KK130P-02MS KQ2H06-02S KQ2H08-02S KQ2H10-02S KQ2H07-35S KQ2H09-35S KQ2H11-35S Threaded Thread size High efficiency nozzle S coupler plug Model no. of coupler used Low noise nozzle with male thread Metric size one-touch fitting Model no. of fitting used Extension nozzle Inch
IBG: IBG, Type: 1 (Standard), Adjuster: 1 (with Adjuster), Supply Port: 12 (S Coupler: KK130P-03MS)
IBG: IBG, Type: 1 (Standard), Adjuster: 1 (with Adjuster), Supply Port: 12 (S Coupler: KK130P-03MS), Nozzle: 13 (Long Nozzle with a Silencer, 150mm)
Any plug side (KK130P-□) and socket side (KK130S-□) combination of the KK130 series can be connected.
Select a model according to the type and size of the tubing or hose to be piped. Refer to the catalog for details.
The KK series catalog can be found here.
IBG: IBG, Type: Standard, Adjuster: with Adjuster, Supply Port: S Coupler: KK130P-03MS, Nozzle: -
IBG: IBG, Type: Standard, Adjuster: with Adjuster, Supply Port: S Coupler: KK130P-03MS, Nozzle: Long Nozzle with a Silencer, 150mm
Table 3.9-1 Function codes NO Code Name Function 1 04(04h) read holding registers Reading multiple registers 2 06(06h) preset single register Writing registers1 3 16(10h) preset multiple registers Writing multiple registers 1 : Broadcast is not supported. 3.10 Checksum calculation method 3.10.1 LRC(ASCII) LRC checks the content of the message other than [:] of START and [CR][LF] of END.
Table 3-7 Function codes NO Code Name Function 1 04(04h) read holding registers Reading multiple registers 2 16(10h) preset multiple registers Writing multiple registers HRLE Series 3.9 Function codes 3-7 HRX-OM-Z015 Chapter 3 Serial communication 3.10 Checksum calculation method 3.10.1 LRC(ASCII) LRC checks the content of the message other than [:] of START and [CR][LF] of END.
Protocol Modbus Master / Slave Slave Letter code ASCII Slave address (Unit number) Select from 01H to 0FH Function code 03H, 06H, 10H, 17H Error check LRC method Data transfer direction LSB 5.3 Setting and checking 5.3.1 List of Items to be Set and Checked The table below explains the setting options of the MODBUS communication function.
01h MAC ID 063 02 0125kbps 1250kbps 2500kbps 03h 01h 02h Data Rate 18 - 4.2 EDS EDS EDSURL URL http://www.smcworld.com ///JXCD1_ PLC 4.3 DeviceNet 1Step Data Class 67h Identity 01h 01h Message Router 02h 01h Device Net 03h 01h Assembly 04h 3 Input64h66h and 4 Output6Eh71h Connection 05h 1 Explicit01h and 1 I/O Polled02h Step Data 67 hex01h40h IO 68 hex01h / 0Eh Get_Attribute_Single 10h