Supply: -, Options: -, Accessories/options: ordered separately: Drop prevention cover (for 4 fixed emitter cartridges), I/O specifications: None, Connector options: -, Model: Accessories (ordered separately), Bar length(mm): None, Emitter cartridge type: None, Emitter material: None, Single-action fittings: None, Sensor: None, Custom-made specifications: None, Compatible: Optional part for IZS40
Range(MPa): -, Power Supply: -, Options: -, Accessories/options: ordered separately: None, I/O specifications: None, Connector options: -, Model: Accessories (ordered separately), Bar length(mm): None, Emitter cartridge type: High-speed ionizing cartridge, Emitter material: Silicon, Single-action fittings: None, Sensor: None, Custom-made specifications: None, Compatible: Optional part for IZS40
MPa): -, Power Supply: -, Options: -, Accessories/options: ordered separately: None, I/O specifications: None, Connector options: -, Model: Accessories (ordered separately), Bar length(mm): None, Emitter cartridge type: Energy-saving ionizing cartridge, Emitter material: Tungsten, Single-action fittings: None, Sensor: None, Custom-made specifications: None, Compatible: Optional part for IZS40
If the MAIN or ION/HV LED is blinking red on an IZS40 or the MAIN, ION/HV, NDL, RC, or SNSR LED is blinking red on an IZS41/42, the CPU is malfunctioning due to noise, etc. Possible countermeasures include ① keeping the ionizer away from the noise source, ② separating wiring if the power line and ionizer are wired together, and ③ installing a noise filter in the ionizer power supply.
.· Standard type IZS40 Simple operation, just power on to use.· Feedback sensor type IZS41 Feedback sensor provides high-speed ionization.· Dual AC type IZS42 Uses dual AC method to reduce electrical potential amplitude of workpiece.
The family includes the standard IZS40 model, the IZS41 with feedback or auto balance sensor and rapid static neutralization, and the IZS42 with low amplitude ion generation for sensitive electronics. The IZS41 and 42 are remote control capable, and can be linked via cable for operation from a single power supply.
The family includes the standard IZS40 model, the IZS41 with feedback or auto balance sensor and rapid static neutralization, and the IZS42 with low amplitude ion generation for sensitive electronics. The IZS41 and 42 are remote control capable, and can be linked via cable for operation from a single power supply.
Model: IZS40~42, Type: Energy Saving High-efficiency, Emitter Material: Tungsten, White
Select R, U, NS, or NZ for the valve when the SI unit output polarity is negative common. * Only Z and NZ are available with a power-saving circuit. Nil None H Built-in !
Nil R R U S Z NS NZ Internal pilot External pilot Non-polar Positive common t Back pressure check valve (Built-in valve type) Negative common Nil H None Built-in Select a valve from R, U, S or Z when the SI unit specification is positive common. Select a valve from R, U, NS or NZ when the SI unit specification is ZBN (negative common).
W-NS: Red LED is ON. No remote are connected. W-NS: Orange LED is ON. Forced output. The base has been set to Forced output mode. Change the mode according to the application. The system has been set to Paring enable. Change the setting to Paring disable when pairing is not conducted. W-NS: Red/green Wireless communication connection is in paring mode. W-NS: LED is OFF.
W-NS: Red LED is ON. No remote are connected. W-NS: Orange LED is ON. Forced output. The base has been set to Forced output mode. Change the mode according to the application. The system has been set to Paring enable. Change the setting to Paring disable when pairing is not conducted. W-NS: Red/green Wireless communication connection is in paring mode. W-NS: LED is OFF.
SI unit SI unit Refer to fault PWR LED and malfunction No.1 MS LED is OFF SI unit Refer to fault PWR(V) LED is OFF No.2 Yes No SI unit Refer to fault MS LED is red No.3 SI unit Refer to fault MS LED is red flashing No.4 SI unit SI unit Refer to fault MS LED is green flashing NS LED is OFF No.5 SI unit Refer to fault NS LED is red No.6 SI unit Refer to fault NS LED is red No.7 flashing SI
(de-energized) 980 m/s2 in X, Y, Z directions 3 times each (de-energized) 500 Vp-p, Pulse width 1 s, Rise time 1 ns Connection Material Weight Power supply / Output connection: 8P connector, Sensor connection: 4P connector (e-con) Housing: PBT, Display: PET, Backside rubber: CR 60 g (Except for any accessories that are shipped together.
Display the error code on LCD. 3 1/2 digits (5 mm-size numerals) Overcurrent, Overpressure, Data error Pressure during 0 clear 0 to 60C (No dewing) 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Between external terminals and housing 1000 VAC, 50/60 Hz for 1 min.
NS Green LED is flashing EtherNet/IP communications not established.
NS Green LED is flashing EtherNet/IP connection is not established.
NS LED is OFF The power supply for control and input is OFF, or IP address is not set. The unit received an IP address, but connection is not established. Green NS LED is flashing Green NS LED is ON Connection is established. Connection timeout.
Green MS LED is ON and NS LED is OFF. Communication is normal. Green MS and NS LEDs are both ON. Connection is not established. Green MS LED is ON and Green NS LED is flashing. A component failure inside the SI unit. Red MS LED is ON. Fatal communication error. (Check the following items, and restart.) Check/correct the node address.
SI unit NS LED is No.8 red ON Refer to fault SI unit NS LED is No.9 red flashing Refer to fault SI unit NS LED is No.10 green flashing SI unit NS LED is green ON All valves and Refer to fault valve LEDs are No.11 not operating Valves do not work but valve LEDs are Refer to fault No.12 operating -38No.EX-OMX1001 Troubleshooting table Fault No.1 Fault Probable cause Recommended error handling