SMC Corporation of America
Elite Part Number Search
Search Results "ITV2030-SPN-2-DUX02357-X26"

Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: 0.005~0.5Mpa, Protocol: PROFINET, Thread: NPT, Port: 2 [1/4, (1000, 2000)], Made to Order: -

Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: 0.005~0.5Mpa, Protocol: PROFINET, Thread: NPT, Port: 3 [3/8, (2000, 3000)], Made to Order: -

Body Size: 20 (1500 L/min), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SEN (EtherNet/IPâ„¢), Thread: Rc, Port: 2 (1/4", 1000, 2000), Made to Order: X26 (Manifold Mounting)

Body Size: 1500 L/min, Pressure Range: 0.005 ~0.5Mpa, Fieldbus: EtherNet/IPâ„¢, Thread: Rc, Port: 1/4", 1000, 2000, Made to Order: Manifold Mounting

Body Size: 10 (200 L/min [ANR]), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)

Body Size: 10 (200 L/min [ANR]), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)

Body Size: 20 (1500 L/min), Pressure Range: 10 (0.005~0.1Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)

Body Size: 20 (1500 L/min), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)

Body Size: 20 (1500 L/min), Pressure Range: 90 (-1.3 ~ -80 kPa) Vacuum, Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)

Body Size & Pressure Range: Body Size: 200 L/min [ANR]; Pressure Range: 0.005~0.5Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: -

Body Size & Pressure Range: Body Size: 200 L/min [ANR]; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: -

Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: 0.005~0.1Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: -

Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: 0.005~0.9Mpa, Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: -

Body Size & Pressure Range: Body Size: 1500 L/min; Pressure Range: -1 ~ -80 kPa [Vacuum], Protocol: PROFINET, Thread: Rc, Port: 2 [1/4, (1000, 2000)], Made to Order: -

0 70 _ _ 4 0 17.6 _ _ 0 1 2250 _ _ 2 1 66 _ _ 4 1 16.5 _ _ 0 2 1125 _ _ 2 2 62 _ _ 4 2 15.6 _ _ 0 3 750 _ _ 2 3 59 _ _ 4 3 14.8 _ _ 0 4 562 _ _ 2 4 56 _ _ 4 4 14.1 _ _ 0 5 450 _ _ 2 5 53 _ _ 4 5 13.4 _ _ 0 6 375 _ _ 2 6 51 _ _ 4 6 12.8 _ _ 0 7 321 _ _ 2 7 48 _ _ 4 7 12.2 _ _ 0 8 281 _ _ 2 8 46 _ _ 4 8 11.7 _ _ 0 9 250 _ _ 2 9 45 _ _ 4 9 11.3 _ _ 0 A 225 _ _ 2 A 43 _ _ 4 A 10.8 _ _ 0 B 204

For the ITV2030, ±2% of the 0.5 MPa pressure range F.S. (full span) is ±0.01 MPa. “±1 digit or less” means that the smallest unit of the value on the output pressure display may vary.
The sum is ±0.011 MPa. This means that for the ITV2030, there may be a small difference between the actual output pressure and the displayed pressure, but it will be within ±0.011 MPa.

Occupied byte Unit Unit part number Input Output EX600-SPN (32 outputs) 0 4 SI unit EX600-SPN (32 outputs diagnostic) 4 4 EX600-DXB (8 inputs) 1 0 EX600-DXC (8 inputs) (with open circuit detection) 1 0 EX600-DXD Digital input unit (16 inputs) 2 0 EX600-DXE (16 inputs) 2 0 EX600-DXF (16 inputs) 2 0 EX600-DYB (8 outputs) 0 1 EX600-DYE (16 outputs) 0 2 Digital output unit EX600-DYF (16 outputs

] (3)[Properties][Device name][Edit Ethernet Node][Device name] (4)[Assing IP address via IO controller] (5)[OK] (1) (2) (3) (4) (5) -60No.EX-OMQ0015CN (1)[HW Config]EX600-SPN# (2)[Configuration table]EX600-SPN# (3)[Hardware Catalog]0 [Configuration table]1 1=2 0=1 (4)SI SI2SI Type1: EX600-SPN (32 coils) ---4 Type2: EX600-SPN (32 coils Status) ---4 4 (1) (2) (3) (4) -61No.EX-OMQ0015CN

"EX260-SPN (EX260-SPN-1, EX260-SPN-2, and so on)" should be entered in the Device name box for each EX260-SPN1/2 or EX260-SPN3/4 set with the hardware configuration. The same name must be used for the connected SI unit device name (page 18) and the device name set in the hardware configuration.