SMC Corporation of America
Elite Part Number Search
Search Results "ITV1050-SPN-1-DUX02357"

Diagnostics type 1 Table. 5-1 Overview of Diagnostics type 1 Byte Description 0 General diagnostics 1 1 General diagnostics 2 2 Valve diagnostics 1 3 Valve diagnostics 2 General diagnostics 1 Table. 5-2 General diagnostics 1 Bit Description Explanation 0 System fault 0: No error on Diagnostics data on I/O mapping 1: At least one error on Diagnostics data on I/O mapping has occurred 1 Valve-coil

GSD 2 3 SI . 4-1 SI EX245-SPN FX EX245-SPN1A EX245-SPN Cu EX245-SPN2A EX245-SPN3A 22 No.EX-OMW0014CN-A 4.1.3.

/Program No. selection 3 DI2 1 0 1 Program No. 6 DI-1 1 1 0 Program No. 7 1 1 1 Program No. 8 Note. 0: off 1: on Program input 1 PI1 Turn PI1 on to resume the step stopped by the SINK (1) command in the program.

Dead band (D.B) Target value Deviation D.B Stroke 2 0% Time Fig. 29 No.IP8S-OM09 34 Valve opening characteristic can be selected from the following. (700) Valve opening (700) = Lin Linear characteristics setting Y=X (710) = EP25 Equal percentage 1:25 (R=25) Y=(RX-1-0.04)1/0.96 (720) = EP50 Equal percentage 1:50 (R=50) Y=(RX-1-0.02)1/0.98 (730) = qo25 Quick opening 25:1 (R=25) Y=(1-R-X)1/0.96

Body Size: 10 (200 L/min [ANR]), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SEN (EtherNet/IPâ„¢), Thread: Rc, Port: 1 (1/8", 1000)

Body Size: 200 L/min [ANR], Pressure Range: 0.005 ~0.9Mpa, Fieldbus: EtherNet/IPâ„¢, Thread: Rc, Port: 1/8", 1000, Made to Order: -

This is a legacy product, and replaced byITV1030-SEN-1-DUX02357, Operation Manual, N, ITV, "REGULATOR, N lb

Body Size: 10 (200 L/min [ANR]), Pressure Range: 10 (0.005~0.1Mpa), Fieldbus: SPN (PROFINET), Thread: N (NPT), Port: 1 (1/8", 1000)

Body Size: 10 (200 L/min [ANR]), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)

Body Size: 10 (200 L/min [ANR]), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SPN (PROFINET), Thread: N (NPT), Port: 1 (1/8", 1000)

Body Size: 20 (1500 L/min), Pressure Range: 10 (0.005~0.1Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)

Body Size: 20 (1500 L/min), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)

Body Size: 20 (1500 L/min), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 3 (3/8", 2000, 3000)

Body Size: 20 (1500 L/min), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SPN (PROFINET), Thread: N (NPT), Port: 2 (1/4", 1000, 2000)

Body Size: 20 (1500 L/min), Pressure Range: 30 (0.005 ~0.5Mpa), Fieldbus: SPN (PROFINET), Thread: N (NPT), Port: 3 (3/8", 2000, 3000)

Body Size: 20 (1500 L/min), Pressure Range: 50 (0.005 ~0.9Mpa), Fieldbus: SPN (PROFINET), Thread: Rc, Port: 2 (1/4", 1000, 2000)