Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 15 (NPN Open Collector 1 Output), Wiring Specification: L (Grommet Lead Wire 3m)
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: NPN Open Collector 1 Output, Wiring Specification: Grommet Lead Wire 3m
Clean gas filter TS-1500 0.17m 15l/min Measuring instrument Minimum measurable particle diameter Suction flow rate Clean gas filter Hitachi Electronics Engineering Co. Ltd.
Clean gas filter TS-1500 0.17m 15l/min Measuring instrument Minimum measurable particle diameter Suction flow rate Clean gas filter Hitachi Electronics Engineering Co. Ltd.
Clean gas filter TS-1500 0.17m 15l/min Measuring instrument Minimum measurable particle diameter Suction flow rate Clean gas filter Hitachi Electronics Engineering Co. Ltd.
Clean gas filter TS-1500 0.17m 15l/min Measuring instrument Minimum measurable particle diameter Suction flow rate Clean gas filter Hitachi Electronics Engineering Co. Ltd.
Clean gas filter TS-1500 0.17m 15l/min Measuring instrument Minimum measurable particle diameter Suction flow rate Clean gas filter Hitachi Electronics Engineering Co. Ltd.
Clean gas filter TS-1500 0.17m 15l/min Measuring instrument Minimum measurable particle diameter Suction flow rate Clean gas filter Hitachi Electronics Engineering Co. Ltd.
HEC006 8 to 15L/min And HEC012 10 to 15L/min When the flow rate of the radiating water is not enough, cooling capacity will decline. Meanwhile, when the flow rate is extremely small, alarm (Err14) may occur and the temperature of the radiating water might be extremely high. If a resin tubing is used for piping under these circumstances, the tubing might get softened and exploded.
MHR3-10R/MDHR3-10l MHR3-10R/MDHR3-10l 10 10 Pressure 0.6MPa 0.6MPa Pressure 8 8 0.5MPa External hold 0.5MPa Holding force (N) Holding force (N) 6 6 0.4MPa 0.4MPa 4 4 0.3MPa 0.3MPa 0.2MPa 2 2 0.2MPa L 0 10 20 30 40 50 0 10 20 30 40 50 Holding point L (mm) Holding point L (mm) Internal hold MHR3-15R/MDHR3-15l MHR3-15R/MDHR3-15l 20 20 Pressure 0.6MPa Pressure 0.6MPa 15 15 L 0.5MPa 0.5MPa Holding
Manually unlocking For 20 to 32 Dust cover holding bolt Dust cover Manual unlocking bolt Manual unlocking bolt Lock ring Locking direction Locking direction Lock ring Rod side Head side Rod side Head side MLGP--F: Extension locking MLGP--B: Retraction locking 1) Remove the dust cover. 2) Screw a manual unlocking bolt (a bolt of M3 x 0.5 x 15L of more commercially available) into the lock
Caution 1) Remove the dust cover. 2) Screw a manual unlocking bolt (a bolt of M3 x 0.5 x 15l or more commercially available) into the lock ring threads as shown above, and lightly push the bolt in the direction of the arrow (head side) to unlock. 1. In order to maintain good performance, operate with clean unlubricated air.
Retraction locking Extension locking 2) Supply air pressure of 0.2MPa or more to unlocking port shown in the drawing on the left. 1) Remove the dust cover. 1) Remove the dust cover. 2) Screw a manual unlocking bolt (a conventional bolt of M3 x 0.5 x 15l or more) into the lock ring threads as shown above, and lightly push the bolt in the direction of the arrow (rod side) to unlock. 2) Screw
Retraction locking Extension locking 1) Remove the dust cover. 1) Remove the dust cover. 2) Screw in the manual unlocking bolt (commercial bolt size M3 x 0.5 x 15l or more) into the lock ring threads, and lightly push it in the direction of the arrow (rear), as shown above, to unlock. 2) Screw in the manual unlocking bolt (commercial bolt size M3 x 0.5 x 15l or more) into the lock ring threads
Retraction locking Extension locking 1) Remove the dust cover. 1) Remove the dust cover. 2) Screw in the manual unlocking bolt (commercial bolt size M3 x 0.5 x 15l or more) into the lock ring threads, and lightly push it in the direction of the arrow (rear), as shown above, to unlock. 2) Screw in the manual unlocking bolt (commercial bolt size M3 x 0.5 x 15l or more) into the lock ring threads
Retraction locking Extension locking 1) Remove the dust cover. 2) Screw a manual unlocking bolt (a bolt of M3 x 0.5 x 15l or more commercially available) into the lock ring threads as shown above, and lightly push the bolt in the direction of the arrow (head side) to unlock.
Caution 1) Remove the dust cover. 2) Screw a manual unlocking bolt (a bolt of M3 x 0.5 x 15l or more commercially available) into the lock ring threads as shown above, and lightly push the bolt in the direction of the arrow (head side) to unlock. 1. In order to maintain good performance, operate with clean unlubricated air.
Pressure Range: L (0~100kPa), Port Size: 01 (Single Unit Mounting R(PT) 1/8), Output Specification: 15 (NPN Open Collector 1 Output)
Pressure Range: L (0~100kPa), Port Size: 01 (Single Unit Mounting R(PT) 1/8), Output Specification: 15 (NPN Open Collector 1 Output), Wiring Specification: CL (Connector Style Lead Wire Length 3.0m)
Pressure Range: L (0~100kPa), Port Size: 01 (Single Unit Mounting R(PT) 1/8), Output Specification: 15 (NPN Open Collector 1 Output), Wiring Specification: C (Connector Style Lead Wire Length 0.6m)