3 EVS7 6 FG M0 Valve Size 6 8 10 Thread type Size 1 Nil F T Rc Size 2 G Size 3 NPTF Passage symbol Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Number of solenoids Port size (A) 4 (B) 2 S D Single Piping specifications Symbol Size 2 Size 3 Size 1 FG Double Nil
B06 Bottom piping: 3 4 Ordering source area code Code Japan, Asia Australia areas E Europe N North America Dimensions Symbol Model VS7-2A03 A04 VS7-2B03 B04 VS7-2-A06 Port size Piping Side A B C D E F G H J K L M N O P Q R S T U V W X Y 62 4-M6 Depth 10 , 3 8 1 2 75 98 30 50 49 32 23 42 31 36 88 10 16 12 16 10 38 16 23 112 15.5 47.5 Bottom Side 4-M6 Depth 12 72 3 4 86 42 63 62 42 30 55 42
The ISE20B-S is a digital pressure sensor with all standard features of the ISE20B, while integrating an M12 connection. M12 permits a stable connection for sensor installations outside a cabinet. The sensor has an informative, easy to read 3 screen, 3 color display.
ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.
ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Connector Type: S (M12 connector type), Bracket: A5 (Bracket E for M12 Connector Type)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Connector Type: S (M12 Connector Type), Bracket: A5 [Bracket E for M12 Connector Type (ZS-46-A5)]
IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.
-2No.PS-OMS0006CN-G / *3) 1 1.5 3) 1 1 -3No.PS-OMS0006CN-G () () () () -4No.PS-OMS0006CN-G () * UL UL1310 2 UL1585 2 30 Vrms(42.4 V ) (2 ) UL (1 20 ) -5No.PS-OMS0006CN-G * FG (35 N () ,() *() 6 33 () () 30m DC(-)() * -6No.PS-OMS0006CN-G ( ) () CE/UKCA -5~50(5 ) * , 1015 10 1% 2053 LCD * -7No.PS-OMS0006CN-G N M5 ISE20 3 ISE20 -0.1001.000 MPa Y ZSE20 0.0-101.0 kPa K ZSE20F
1.5 3) 3) 1 1 () [] -3No.PS-OML0002CN-G () () () () -4No.PS-OML0002CN-G () * UL UL1310 2 UL1585 2 30[Vrms] 42.4[V ]2 UL (100 10 ) JIS B 8392-1 11.1.21.6.2:2003 () -5No.PS-OML0002CN-G * / / ,FG (35N ) () () * () 6 33 () () 10 m DC(-)() () * -6No.PS-OML0002CN-G ( ) () CE 050(5), * ON , 1015 10 /1 2146 LCD * -7No.PS-OML0002CN-G 01 N ISE30A 3 ISE30A -0.11 MPa Y
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type)
Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -
MPa ISE20B ISE20B: 0.050 MPa/ZSE20B: 5.1 kPa/ ZSE20BF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20B(F) Safety Instructions Bracket A ISE20B Delay time 1.5 ms or less Bracket B psi P ZSE20B(F) Display color OUT1 ON: Green/OUT1 OFF: Red : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Units specification Pressure range Default setting ISE20B: 0.050 MPa/ZSE20B: 5.0 kPa/ ZSE20BF: 5.0 kPa Hysteresis ISE20B MPa "Nil" or M ZSE20B(F) kPa Delay time 0.00 sec.
Bracket mounting inserts found on the standard ISE20B are omitted as well. 25A-ISE20B is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
Bracket mounting inserts found on the standard ISE20B are omitted as well. 25A-ISE20B is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
ISE20B is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
ISE20B-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
ISE20B-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
ISE20B-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.