2 16..25 0..7 Refer to above Refer to above PortConfig Por t 3 26..35 0..7 Refer to above Refer to above PortConfig Por t 4 36..45 0..7 Refer to above Refer to above -111No.EX-OMZ0024 Parameter setting of IO-Link device with configuration assembly The Configuration assembly function enables PCL to send parameters to the IO-Link device, which is connected to the IO-Link master, under the
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Port size M5 x 0.8 t 10.5 15 18 20 t 10.5 15 18 20 Series Assembly part no.
Fittings & Tubing Air Cylinders Rotary Actuators 3(R2) 1 (P) (R1)5 1 (P) (R1)5 3(R2) t e q t r w qr w (B) 2 (A) 4 (B) 2 (A) 4 u u 3 (R) 1 (P) 5 (R) 3 (R) 1 (P) 5 (R) y 3 position closed center/exhaust center/pressure center 3 position closed center 2(B) (A)4 q t r w 3(R2) 1 (P) (R1)5 (B) 2 (A) 4 3 position exhaust center 2(B) (A)4 3(R2) 1 (P) (R1)5 3 position pressure center u 2(B) (A)4 3
Port size M5 x 0.8 t 10.5 15 18 20 t 10.5 15 18 20 Series Assembly part no.
N.O. 3(R) (P)1 3(R) (P)1 e t q r e t q r (A) (A) 2 2 u u 3 (R) 1 (P) 3 (R) 1 (P) w w y y Component Parts Replacement Parts Note Zinc die-casted Part no.
IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)