Valves can be ordered as normally open or normally closed and pilot actuation can be factory preset.
Do not bend the cable at the root of the connector when installed. * If an insertion label is not to be used, the marker tag can be removed before use. Wiring Caution 1. Do not lay the wires while they are energized. Doing so may give you an electric shock. 2. It should be cabled according to the connection diagram. 3. Check if it can be connected when using a sensor or switch. 4.
Therefore, the equipment to be connected must be below this rating.
A contact protection box should be used in any of the above situations. Otherwise, the life of the contacts may be reduced. (They may stay on continuously.)
To replace them, they must be replaced together with the cover assembly. 2. When the cylinder is used as mounted with a single side fixed or free (basic, flange types), a bending moment will be applied to the cylinder due to the vibration generated at the stroke end, and the cylinder may be damaged.
The larger the effective area is, the shorter the locking time will be (the overrun amount will be shorter), and stopping accuracy will be improved. 3. Place the solenoid valve for unlocking close to the cylinder, and no farther than the cylinder drive solenoid valve.
The larger the effective area is, the shorter the locking time will be (the overrun amount will be shorter), and stopping accuracy will be improved. 3. Place the solenoid valve for unlocking close to the cylinder, and no farther than the cylinder drive solenoid valve.
Note) : Can be used at low temperatures and low concentration.
If the cylinder is to be bottom mounted, bypass ports should be provided for the guide rods.
The load must be guided by other means. The mounting fittings for the load should be designed to meet the weight limits shown in this table.
A contact protection box should be used in any of the above situations. Otherwise, the life of the contacts may be reduced. (They may stay on continuously.)
If the cylinder is operating at a high frequency, be aware that the cylinder tube surface could become very hot, creating the risk of burns. eThe One-Touch fitting cannot be replaced. The One-Touch fitting is press-fit into the cover and cannot be replaced.
Otherwise, lock may not be engaged. u Use complete stroke or cylinder at side with lock. If cylinder piston does not reach end of stroke, lock may not be engaged or released. 2. Operating pressure Lock Caution Release Use pressures 0.15 MPa or more at port with locking mechanism. Otherwise, lock will not be released. 3.
*The auto switch mounting bracket material is also restricted. *2 The D-A90L-900 cannot be mounted on the RSH, RS1H, MY1B25 to 63, CDNA50. *3 The D-M9BW(V)-900 cannot be mounted on the MY1B50. *4 Reed switches (D-A90L-900 and D-Z80L-900) cannot be mounted on the MHZJ, MHZL, MHS, MHL series.
Note) : Can be used at low temperatures and low concentration.
Because pipe fittings are press-fit, they must be replaced together with the cover assembly. r Those with a bore of 50 or more cannot be disassembled.