Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRS Series 4.5 Message configuration 4-9 HRX-OM-M091 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1 shows function codes to read or write register.
Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRSH Series 4.5 Message configuration 4-9 HRX-OM-Q033 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1 shows function codes to read or write register.
Response message Code Contents Code Contents 01 Slave Address 01 Slave Address 03 Function 03 Function 0 Head address of specified register 02 Quantity of bytes to read 0001 Quantity of register to read 00EE Information of 0h (circulating fluid discharge temperature: 23.8 oC) FB LRC 0C LRC Request message (Master to Slave) Start Slave Address Function Data LRC End 3A 30 31 30 33 46 42 0D 0A
Read Address Quantity to Read Hi Lo Hi Lo 30 30 34 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 41 34 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 39 34 4D HECR 5-6 MODBUS communication function 5.6 Function codes The table berow function codes to read or write register.
Driver Inrush currents (A0-p) Main circuit power supply (L1, L2, L3) Control circuit power supply (L11, L21) LECSS138A (Attenuated to approx. 14A in 10ms) 20 to 30A (Attenuated to approx. 0A in 1 to 2ms) LECSS230A (Attenuated to approx. 5A in 10ms) Since large inrush currents flow in the power supplies, always use no-fuse breakers and magnetic contactors. (Refer to section 11.6.)
Setting Output device (Note) Name Symbol 00 Always OFF 02 Ready RD 03 Trouble ALM 04 In position INP 05 Electromagnetic brake interlock MBR 06 Dynamic brake interlock DB 07 Limiting torque TLC 08 Warning WNG 09 Battery warning BWNG 0A Speed command reached SA 0C Zero speed ZSP 0F Variable gain selection CDPS 23 Rough match CPO 24 Home position return completion ZP 25 Position range POT 26
OFFSET Device Type/Name DEVICE_ CODE 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 Model 00H S G D 1 1 2 2 2 3 4 4 5 6 6 6 6 6 6 00 DRIVER Ver. 02H Software version Model 20H S G M 7 7 8 8 9 10 11 12 13 00 Servomotor Ver. Encoder software version 12H Model 30H External Encoder Software version 32H Ver.
.|0220V + 10% {50/60H2) OC24V +2V Power ConaumDlion 5OVA 29W Culput Currenl Rang 0-0.7sA 0-1A lmpdance ot E/P Proporlional Valve 26-36a (o.7sAF.S.) 13-18.sa 0A F.S.)
Series VMG Pressure loss Conventional model %FFECTIVE area 30 mm2 %FFECTIVE area 6 mm2 0.3 Energy saving valve construction "ALANCE POPPETVALVECONSTRUCTION Conventional construction Pressure loss [MPa] 0.25 0.2 Conventional model &OREXAMPLE WHENYOU compare THIS WITHTHIS This is the result VMG (Nozzle size: 2.5) 0.15 0RESSURELOSS 0.005 MPa or less WITH-0A 0.1 0.05 0 PAT.PEND 0 0.2 0.4 0.6
id=MK-Z-E>MK%20series%20catalogs</a></span><br></p></dd></dl>%0A%0A</div>">
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, 1.08657 lb, ModelPressure rangeProof pressureFluidDimensionsPower supplyInputPower supply outputCommand outputSwitch outputSwitch responseDisplayDisplay accuracy Note 1)Display sampling rateTemperature characteristicsError
mode / output style 17 Line name (left side 4 digits, right side 5 digits) 18 Display channel 19 CH1 measurement display value 20 CH2 measurement display value 21 CH3 measurement display value 22 CH4 measurement display value 23 Display OFF (No display) : Settable : Not settable (negative acknowledge) -94No.PS-OMW0012-C Value (16 Hex number) 00 01 02 03 04 05 06 07 08 09 0A
12 Wind mode upper side set value 13 Wind mode hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode display -87No.PF-OMZ0002-A [Line name communication data] Value (16 hex number) 00 01 02 03 04 05 06 07 08 09 0A
12 Wind mode upper side set value 13 Wind mode hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode display -83No.PF-OMY0002 [Line name communication data] Value (16 hex number) 00 01 02 03 04 05 06 07 08 09 0A
hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode (Refer to page 13) 22 Option display Line name, not displayed -83No.PF-OMX0002-B [Line name communication data] Value (16 hex 00 01 02 03 04 05 06 07 08 09 0A
hysteresis OUT2 14 Accumulated output mode 15 Accumulated pluse output mode 16 Err mode 17 oFF mode 18 Flow bottom value 19 Flow peak value 20 Accumulated flow value 21 Switch output mode/communication mode display SIO mode/SDCI mode (Refer to page 13) 22 Option display Line name, not displayed -48No.PF-OMX0007-A [Line name communication data] Value (16 hex 00 01 02 03 04 05 06 07 08 09 0A
name (left side 4 digits, right side 5 digits) 17 Display channel 18 CH1 measurement display value 19 CH2 measurement display value 20 CH3 measurement display value 21 CH4 measurement display value 22 Display OFF (No display) : Settable : Not settable (negative acknowledge) -87No.PF-OMA1011-A [Line name communication data] Value (16 Hex number) 00 01 02 03 04 05 06 07 08 09 0A
Amplifier lmpedance 100Ko 3ignal Voltage Range 0-1 0 vDc 0-svDc qppllcable Polentiometer 1OKA (1/8W or above) not provided itep Besponse 60ms (0.75A,95'/d )lther Frequency Adlustable Range 100-200 Hz (Factory adjusted @ 125H2) 12Q-19QHz (Factory adiusted @ 140H2) {ull Adjustable Range 0-0.5A (Factory adjusted @ 0A Sain Adlustable Range 5UU-/5UmA aI an InpUI voltage of 10V 500mA-14 at an input
.| 0 riiqr DIMENSIONS a o E F o It 10.87 (27812.8i, (4 494 (r00) 7.m (197) 1.22 (31) 0.47 0a 2.90 06) 2.88 (88) lnlrs ln Fbronlhoacs SERIES DIRECTIO]IAL AIR VALVES DIMENSIONS/PARTS LIST NVS 4)24,4C34 NVS4O44,454 NVS4?4,42 4,424p T* I !..
F810G06 zFB10r{5,.07 o zFB200-0c zF8201-O7 c zFB2m-m o zFB3tx)-0a,-10 zFB30tnl o zFB401-13 Application To Ejector Type System 0 014 (0.001) 0.007 (0.00os) 0.0043 (0.0003) (s) 0.1 18 0.25 0.35 (51 (4 (1ol 1 . r 1 . 8 2 . 5 3 5 7 . 1 (mo) (301 (5ol (70] (1001 Flow SCFM (N/min) Construction/Packing List =t O Insta a on . th6ck caretully lN and OUT locations before mounting. .