Model determination 61 Series REBR Model Selection 2 Design Parameters 1 Selection Method REBR25 REBR32 REBR15 500 400 300 200 300 200 Allowable driving force Fn (N) Load weight W (kg) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 100 40 30 40 50 20 30 40 50 30 20 20 Usable range 10 10 10 Usable
Find the drive resisting force Fn (N) when moving the load horizontally. CY3B6 CY3B32 400 300 200 40 30 20 Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) 2.
Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 40 30 20 20 30 40 50 3. Select the bore size and type of magnet holding force (types H, L) from Lo and Fn based on data K A .
Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 40 30 20 20 30 40 50 3. Select the bore size and type of magnet holding force (types H, L) from Lo and Fn based on data K A .
XMC Exterior dimensions C D L1 L2 Fn Fc C (Fc) (KF Flange) (CF Flange) J H B A G A Unit:mm Model A B C D Fn Fc G H J P.C.D L1 L2 XMC-16 40 110 38 1 30 34 17 40 26 P.C.D 27 6x4.4 XMC-25 50 120 48 1 40 26 39 28 XMC-40 65 171 66 2 55 70 41 63 36 P.C.D. 58.7 6x6.6 C D L1 L2 Fn Fd Fc C (Fc) (KF Flange) (K Flange) (CF Flange) H J K B A G A Unit:mm Model A B C D Fn Fc Fd G H J K P.C.D L1 L2 XMC-
Foundation bolt L1 (mm) Nominal thread size d M16 L1 R Applicable model d1 S L Part No. (Approx.) (Approx.) FGF-OP05 Hexagon nut d FGF1-20 16 40 71 31.5 400 R d1 FGF3-40 AI-3S M20 20 50 90 40 500 FGF5-60 S Note) 3 foundation bolts are required per filter unit. If ordering only foundation bolts, order 3 bolts using the above part number.
Dimensions C D L1 L2 Fd Fc C Fn (Fc) (KF Flange) (K Flange) (CF Flange) K B J H A G A Unit: mm Model A B C D Fn Fd Fc G H J KK P.C.D.
Pivoting Nozzle with Self-Align Fitting / KNK (mm) Model Nozzle diameter D Connection size L1 L2 With across flats H1 H2 H3 17 19 24 27 KNK-10-600 KNK-12-600 KNK-16-600 KNK-20-600 10 12 16 20 6 6 6 6 17 17 17 17 17 17 24 27 17 17 17 17 41.7 41.2 41.8 43.8 35 D H3 H1 H2 L1 L2 8.5 Pivoting Nozzle with Male Thread / KNK (mm) Model Nozzle diameter D Connection size L1 A With across flats H1 H2
Select the bore size from Lo and Fn based on data A .
Dimensions XMH series / Angled Valve C D L1 L2 A Fn Fc C (Fc) (CF Flange) (KF Flange) H J H B G A Unit:mm Table 5 Model A B C D Fn Fc G H J P.C.D L1 L2 XMH-16 40 100.5 38 1 30 34 17 35 18 P.C.D 27 6x4.4 XMH-25 50 114 48 1 40 26 41 21.5 XMH-40 65 162.5 66 2 55 70 41 57 30 P.C.D 58.7 6x6.6 XMH-50 70 179.5 79 2 75 52 70 35 XYH series / Straight Valve D G C C B H Fn J (KF Flange) 45 Unit: mm
Exterior dimensions C D XMA Series Angle Valve Fd Fn Fc C Fc L1 KF Flange K Flange CF Flange ( K ) ( K F ) ( C F ) L2 H B G A A Unit:mm Model n Fd Fc H P.C.D L1 L2 XMA-16 40 103 38 1 30 34 17 40 P.C.D 27 6x4.4 XMA-25 50 113 48 1 40 26 39 XMA-40 65 158 66 2 55 70 41 63 P.C.D. 58.7 6x6.6 XMA-50 70 170 79 2 75 52 68 XMA-63 88 196 100 3 87 95 114 70 69 P.C.D. 92.1 8x8.4 XMA-80 90 235 117 3 114
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, TOP PANEL FOR HRZ008-L/L1, OTHERS, HRZ- THERMO CHILLER, 21
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, BY-PASS PIPING SET HRZ008-L1, OTHERS, HRZ- THERMO CHILLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, REAR PANEL FOR HRZ008-L/L1, OTHERS, HRZ- THERMO CHILLER, 21
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, RIGHT PANEL FOR HRZ008-L/L1, OTHERS, HRZ- THERMO CHILLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, LEFT PANEL FOR HRZ008-L/L1, OTHERS, HRZ- THERMO CHILLER, 21
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Compressor Set (HRZ008-L/L1), REFRIGERATED THERMO-COOLER, 737
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Pump Inverter for HRZ008-L1-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Casters (496, 498, HRZ008-L/L1, & HRZD), REFRIGERATED THERMO-COOLER