Cooling Capacity: 15 kW, Type: Ethylene Glycol, Pump Inverter Control: None, Option: D+N+Z
Circulating Fluid: Clear/Deionized Water, 10 to 60°C, Option: D+N+Z
Circulating Fluid: Fluorinated Fluids, -20 to 90°C, Option: D+N+Z
Cooling Capacity: 8kW, Temperature Set Range: -20°C to 90°C, Option: D+N+Z
The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled
The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, THERMO CHILLER, OTHERS, HRZ- THERMO CHILLER, 2X, HRZ - NO SIZE RATING, 374.78584 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, THERMO CHILLER, OTHERS, HRZ- THERMO CHILLER, 2X, HRZ - NO SIZE RATING, .00000 lb
The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type). Energy saving is substantially increased by exchanging cooling water and heat directly. The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly with
Cooling Capacity: 030 (30 kW), Type: Fluorinated Fluid, Pump Inverter Control: S (Pump Inverter Type)
Cooling Capacity: 030 (30 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type)
Cooling Capacity: 030 (30 kW), Type: 1 (Ethylene Glycol)
Cooling Capacity: 030 (30 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: S (Pump Inverter Type)
Cooling Capacity: 030 (30 kW), Type: 2 (Clean/DI Water)
Cooling Capacity: 30 kW, Type: Fluorinated Fluid, Pump Inverter Control: Pump Inverter Type, Option: -
Cooling Capacity: 30 kW, Type: Clean/DI Water, Pump Inverter Control: Pump Inverter Type, Option: -
Cooling Capacity: 30 kW, Type: Ethylene Glycol, Pump Inverter Control: -, Option: -
Cooling Capacity: 30 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: -