SMC Corporation of America
Elite Part Number Search
Search Results "HRW008-H2-DN"

How to Order EX500 G DN 1 Communication protocol Applicable GW unit DN PR AB DeviceNet PROFIBUS-DP Remote I/O (RIO) DeviceNet PROFIBUS-DP Remote I/O (RIO) Nil -X1 Dimensions 148 EX500-GAB1-X1 VOLTAGE 24 VDC/200 mA INPUT/OUTPUT 64/64 IP CODE IP65 SERIAL NO.

How to Order EX500 G DN 1 Applicable GW unit Communication protocol DeviceNet PROFIBUS-DP Remote I/O (RIO) DN PR AB DeviceNet PROFIBUS-DP Nil Remote I/O (RIO) -X1 Dimensions 148 E x 500-GAB1-X1 VOLTAGE 24VDC/200mA INPUT/OUTPUT 64/64 IP CODE IP65 SERIAL NO.

R T Metric (mm) 00T Imperial (Inch) S E R I E S VQ1000 7 Plug Lead unit/cassette type T Y P E O F M A N I F O L D DIN R A I L/ O P T I O N N o t e 1 )D DIN rail mounted type N With Nameplate N U M B E R O F S TAT I O N S N o t e 1 ) Manifold is of a DIN rail mounted type, and so suffix D should be indicated. 01 1 Station 16 16 Stations N o t e 2 ) When the N option is desired, write as DN

reduced facilities investment, space saved facility water facilities, and reduced running cost.Circulating fluids type: fluorinated, ethylene glycol aqueous solution, and clean/DI water, Temperature range setting: 20 to 90 °C, Cooling capacity: 2 kW, 8 kW, 15 kW, and 30 kW, Temperature stability: ±0.3 °C, Ideal for ordinary temperature and high temperature processes, Front Panel for HRW008

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: NZ (N+Z)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: C (Analog Communication)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: Z (Circulating Fluid Automatic Recovery)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: CN (C+N)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: CNZ (C+N+Z)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: D (DeviceNet Communication)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: N (NPT Fitting)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: NYZ (N+Y+Z)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: Y (DI Control Kit)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: NY (N+Y)

Cooling Capacity: 8 kW, Type: Clean/DI Water, Pump Inverter Control: None, Option: Circulating Fluid Automatic Recovery