Applicable cylinder bore size (mm) Speed controller with Model Port size 4 6 8 10 12 One-touch fittings for AS121-M5 M5 x 0.8 6, 10, 16, 20 1 8 AS221-01 R 20, 25, 32 metal body specifications 1 4 AS221-02 R 20, 25, 32, 40 3 8 AS321-03 R Uses flame resistant resin as standard.
The following procedures are an example of how a test may be performed. It is intended as an overview and not as an all inclusive description. 1) Rotate the adjustment wheel counterclockwise (DECR) completely to relieve spring force.
20 25 25 28 36 24 17.5 25 20 18.5 21 16 16 20 20 25 30 Grooves (Except 12, 16, 20, 25) (mm) Use grooves section a and section b in the figure below of the cylinder body for firmly fixing in the following case.
to 50 M N Bracket (See table below.) 4-O T Q 2-P AH AG B S W K U L AA AL AB A I J AI AJ 4-AK hole V AP R Y + Stroke Z + Stroke X AG For 4-AO AN AI Cutout window AM Mounting dimensions For standard strokes (mm) Bore size (mm) Stroke range (mm) O N M L K J I B AP AO AN AM AH AG AB AA AL AK AJ AI A 20 25 32 40 50 75, 100, 125, 150, 200 M6 x 1 depth 9 45 25 80 60 55 30 108 25 M6 115 65 125 112
0.14 30 0.21 15 0.10 20 0.14 10 0.07 10 0.07 5 0.03 0 0.00 0 0.00 0 20 40 60 80 100 120 Flow rate (slpm, N2) 0 4 8 12 16 20 24 28 32 Flow rate (slpm, N2) Hastelloy is a registered trademark of Haynes International.
Applicable cylinder bore size (mm) Model Metric size Inch size ASP 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS1001F 6, 10, 16, 20 ASN AS2001F 20, 25, 32 AS2051F 20, 25, 32, 40 AQ AS3001F 40, 50, 63 ASV AS4001F 63, 80, 100 AK Flow Rate and Effective Area ASS AS1001F AS2001F AS3001F AS2051F AS4001F Model JIS Symbol Metric size 6 6 8 10 6 8 3.2, 4, 6 4 10, 12 12 ASR Tubing O.D.
~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC Material Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Polyurethane Courtesy of Steven Engineering, Inc. !
The following procedures are an example of how a test may be performed. It is intended as an overview and not as an all inclusive description. 1) Rotate the adjustment wheel counterclockwise (DECR) completely to relieve spring force.
AK VCHC 9. Do not apply excessive force or shock to the body or fittings with an impact tool. 6. Check if PTFE can be used in application. ASR ASQ PTFE powder (Polytetrafluoroethylene resin) is included in the seal material for piping taper thread of male thread type. Confirm that the use of it will not cause any adverse effect on the system.
T 2 x P (Rc, NPT, G) Q AH AG S U W K L B R A AL I J AI AJ AP 4 x AK hole AA AB V Y + Stroke X Z + Stroke For 4 x AO AG AN AI Cutout window AM Mounting dimensions (mm) Bore size (mm) 20 25 32 40 50 Stroke range (mm) AA AB AG AH AI AJ AK AL AM AN AO AP B I J K L M N O A 11 11 112 125 82 95 6.6 9 65 115 M6 25 108 30 55 60 80 25 45 M6 x 1 depth 9 90 75, 100, 125, 150, 200 14 13 134 150 92 108
with an are the same as standard.
22.4) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 0 0.00 0 20 40 60 80 Flow rate (slpm, N2) AK1000HF 100 psig (0.69 MPa) 30 psig (0.21 MPa) Inlet pressure: 50 psig (0.34 MPa) 60 0.41 50 0.34 Delivery pressure (psig) Dlivery pressure (MPa) 40 0.28 30 0.21 20 0.14 10 0.07 0 0.00 0 20 40 60 80 100 120 140 160 180 200 Flow rate (slpm, N2) Hastelloy is a registered trademark of Haynes International
The following procedures are an example of how a test may be performed. It is intended as an overview and not as an all inclusive description. 1) Rotate the adjustment wheel counterclockwise (DECR) completely to relieve spring force.
Note 4) 2 locations on the back side for the standard-type 20 with 15 strokes or less and 25 with 10 strokes, and for models with an auto switch and built-in magnet of 20 with 5 strokes.
This product cannot be used to hold a stop position for an extended period of time. Pilot check valves and actuators are not guaranteed for zero air leakage. Therefore, it is sometimes not possible to hold a stop position for an extended period of time. In the event that holding for an extended time is necessary, a mechanical means for holding should be devised. 3.
2.5 to 6 6 to 20 20 to 40 40 to 63 63 to 100 AS13l1F AS13l1F AS23l1F AS33l1F AS43l1F / 1 8, / 1 4 / 1 4, / 3 8 / 1 2 Elbow (Metal Body) M5 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 AS12l1 AS22l1 AS22l1 AS32l1 AS42l1 / 1 8 4.1-7 / 1 4 / 3 8 / 1 2 In-line 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 AS1001F AS2001F AS2051F AS3001F AS4001F 4.1-9 Dual Speed Controller 6 to 20 20 to 32 20
Wiring Specs 20 20 Applicable up to 20 Solenoid M A N I F O L D O P T I O N S PORT PLUGS Applicable Fitting Size d A L D Model 16 32 6 KQP-04 4mm 16 32 6 KQP-03 5/32 18 35 8 KQP-06 6mm 18 35 8 KQP-07 1/4 20.5 39 10 KQP-08 8mm 20.5 39 10 KQP-09 5/16 Inserts easily into an unused cylinder port and/or SUP/EXH Ports.
2 AQ w t y q i o e ASV AK !0 VCHC ASR ASQ u @0 Meter-in type Meter-out type Component Parts No.
The following procedures are an example of how a test may be performed. It is intended as an overview and not as an all inclusive description. 1) Rotate the adjustment wheel counterclockwise (DECR) completely to relieve spring force.
The most typical is an increase in outlet pressure as the inlet pressure decays often stated as a given rise per a given drop in pressure. [Inboard leakage] Leakage rate from outside to inside of the products occurring when an internal pressure is less than the external pressure.