Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz))
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz))
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz))
Cooling Method: Water-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: -
Cooling Method: Air-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: -
Cooling Method: Air-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: -
Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: -
Cooling Method: Water-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: -
with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, LOWER PANEL (HRSH090
integrated with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, MAIN BOARD HRSH090
with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, UPPER PANEL (HRSH090
UNIT, HRSH090, CHILLER, 1.5 lb
the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, O-Ring Set (12-90, HRSH090
the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Mechanical Seal Set HRSH090
of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Power Terminal Cover HRS090/HRSH090
with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Cooling Fan For HRSH090
with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Cooling Fan For HRSH090
grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, FRONT UPPER PANEL ASSEMBLY HRSH090
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: J (w/Automatic Fluid Fill Function)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: M (Applicable to Deionized Water Piping)