Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: M (Applicable to Deionized Water Piping)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: M (Applicable to Deionized Water Piping)

Cooling Method: Air-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: Applicable to Deionized Water Piping

Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: Applicable to Deionized Water Piping

Cooling Method: Water-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: Applicable to Deionized Water Piping

Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH090-A-40, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH090-W-40, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

Inverter compressor, fan, and pump for efficient power consumption ; Cooling capacity: 9.5kW (Air), 11kW (Water) ; Temperature range setting: 5 to 40° C ; Temperature stability: ±0.1° C ; Standards: CE (400V only), RoHS ; Circulating fluid: Tap water, deionized water, or 15% ethylene glycol solution

Inverter compressor, fan, and pump for efficient power consumption ; Cooling capacity: 9.5kW (Air), 11kW (Water) ; Temperature range setting: 5 to 40° C ; Temperature stability: ±0.1° C ; Standards: CE (400V only), RoHS ; Circulating fluid: Tap water, deionized water, or 15% ethylene glycol solution

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz)

Cooling Method: Air-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: -

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: M (Applicable to Deionized Water Piping)

Cooling Method: Air-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: Applicable to Deionized Water Piping

[AF] 0.1 MPa Set pressure range [AR] 0.05 to 0.85 MPa Nominal filtration rating*3 [AF] 5 m Compressed air purity class*4 ISO 8573-1:2010 [ 6 : 4 : ]*5 Drain capacity [AF] 8 cm3 25 cm3 45 cm3 Port size 1/4: 30 L/min (ANR) Port size 3/8: 40 L/min (ANR) Port size 1/2: 50 L/min (ANR) Port size 1/4: 30 L/min (ANR) Port size 3/8: 40 L/min (ANR) Min. dripping flow rate*6 [AL] 15 L/min (ANR) 50

60C (with no freezing) Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range [AR] 0.05 to 0.85 MPa Nominal filtration rating [AF/AFM] AF: 5 m, AFM: 0.3 m (99.9% filtered particle size) Rated flow [L/min(ANR)] [AFM] 3 200 450 450 1100 1100 Outlet side oil mist concentration [AFM] 4 5 Max.1.0 mg/m3 (ANR) (0.8 ppm) Bowl material [AF/AFM] Polycarbonate Bowl guard [AF/AFM

When 40 m is rquired: 1-40 2 If indicating 7 only, the filtration rate is 5 m. Optional filtration rate is required, indicate like 17-. Ex.) When requiring stainless steel and 40 m; 17-40 3 The bowl of series AL is used. 4 This symbol indicates the port size.

JIS Symbol Filtration: 0.3 m AWM20 How to Order AWM40 03 BE F 30 1N AWM Option Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Description Symbol 1 (4) Applicable model AWM20 to 40 AWM20 to 40 AWM20 to 40 AWM30/40 AWM20 AWM30/40 AWM20 to 40 AWM20 to 40 AWM30/40 0.05

Model Port size M B B A B C D P E F G H J K L 8, 1 4 1 40 53 70 75 97.5 129 165 169 11 14 18 20 40 53 70 70 40 56 73 73 17 16 17 14 30 41 50 50 27 40 54 54 22 23 26 25 5.4 6.5 8.5 8.5 8.4 8 10.5 10.5 40 53 70 70 2.3 2.3 2.3 2.3 120.5 AFD2000 AFD3000 AFD4000 AFD4000-06 4, 1 8 3 170 206 210 4 3 2 1 4, 1 8, 3 AFD2000 AFD3000 SAC2000, #1 SAC2503, #1 AFD4000 AFD4000-06 SAC4000, #1 SAC4006,

35.5 M 30 41 50 50 N 27 40 54 54 Q 22 23 26 25 R 5.4 6.5 8.5 8.5 S 8.4 8 10.5 10.5 T 40 53 70 70 U 2.3 2.3 2.3 2.3 AL20-A AL30-A AL40-A AL40-06-A 60 80 110 110 Model Semi-standard specifications With barb fitting B 123.6 155.6 157.6 With drain cock B 87.7 115.1 147.1 149.1 AL20-A AL30-A AL40-A AL40-06-A 57 Modular Type Filter Regulators Series AW AC AFARAL AWAL AFAR AFAFMAR AWAFM AF AFM