SMC Corporation of America
Elite Part Number Search
Search Results "HRSH090-AF-20-MS"

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: S (Conforming to CE/UL Standards)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: B (w/Earth Leakage Breaker)

Cooling Method: Air-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Conforming to CE/UL Standards

20 25 25 28 36 24 17.5 25 20 18.5 21 16 16 20 20 25 30 Grooves (Except 12, 16, 20, 25) (mm) Use grooves section a and section b in the figure below of the cylinder body for firmly fixing in the following case.

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: MS (Applicable to Deionized Water Piping + Conforming to CE/UL Standards)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: MS (Applicable to Deionized Water Piping + Conforming to CE/UL Standards)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: MS (Applicable to Deionized Water Piping + Conforming to CE/UL Standards)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: MS (Applicable to Deionized Water Piping + Conforming to CE/UL Standards)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: MS (Applicable to Deionized Water Piping + Conforming to CE/UL Standards)

Cooling Method: Water-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Applicable to Deionized Water Piping + Conforming to CE/UL Standards

Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Applicable to Deionized Water Piping + Conforming to CE/UL Standards

Cooling Method: Water-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Applicable to Deionized Water Piping + Conforming to CE/UL Standards

Cooling Method: Air-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Applicable to Deionized Water Piping + Conforming to CE/UL Standards

Cooling Method: Water-cooled Refrigeration, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: Applicable to Deionized Water Piping + Conforming to CE/UL Standards

(mm) BF VA 4H9 4H9 5H9 6H9 6H9 ZD 6 10 12 16 20 ZH M3 x 0.5 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 UC M5 x 0.8 M5 x 0.8 M6 x 1 M8 x 1.25 M8 x 1.25 ZJ 3.5 4.5 5 7 8 ZI 6 10 12 16 20 ZG 15 16 18 22 26 ZF 20 21 28 32 41 BG ZE 5 8 10 14 17 CC 9.5 13.5 17.5 20 25 VB 4 4 5 6 6 AJ 9 9 11 13 13 UE 5.5 5.5 6.6 8.6 8.6 AH 9 12 15 18 20 UD 10 10 12 16 16 AG 26 27 33 35 45 FX 22 26 32 40 50 AF 35 36 44

;200 million cycles VQC21fi): 20 ms 2 ms;2fi) million cycles For r,lf, srunh vQc4loo: 17 ms 3 ms; 100 million cycles P!

p 1o 12 stalons Lateral Plug.in Style Manifold series VQCI 000/20044000 r t Fast response times and long service life VQCl100: 10 ms 2 ms; 200 million cycles VQC2100: 20 ms 2 ms; 200 million cycles VQC4100: 17 ms 3 ms; 100 million cycles ( ( I T CE compliment " , t 4-position dual 3-pod valves for independent control of A & B ports Availabe conf igurations IN.C.A.C.], lN.O /N.O l, and [N.c

AV Response time 10 ms 30 ms Fluid Air/Inert gas AU 0 to 50C (With no condensation) Ambient and fluid temperature AF 0.88 MPa Maximum operating pressure Regulating pressure range 0.05 MPa to supply pressure AR Set pressure to 0.88 MPa (VY101) External pilot pressure (Direct operated) 1 to 5 VDC, 0 to 10 VDC, 4 to 20 mA DC, 0 to 20 mA DC Command signal IR 12 VDC 10%, 24 VDC 10%, 1.8 W

-6 1 1 1 0 2.5 5 7.5 10 0 2.5 5 7.5 10 0 2.5 5 7.5 10 V V V VY130-7 VY140-7 VY150-7 2 2 2 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA 4 0 8 12 16 20 mA VY130-8 0 5 10 15 20 VY140-8 0 5 10 15 20 VY150-8 0 5 10 15 20 3 3 3 mA mA mA Command signal Command signal Command signal VY1700 1 VY1900 1 Input signal voltage (current) for starting the operation of a pilot valve VY1D0 (direct operated) (There

HED Polypropylene skid HEA Model Weight [kg] Dimensions [mm] HRSE012-A-10 35 Height 745 x Width 465 x Depth 575 HRSE018-A-10 HRSE012-A-10-T 42 Height 745 x Width 465 x Depth 620 HRSE018-A-10-T HRSE012-A-20 38 Height 745 x Width 465 x Depth 575 HRSE018-A-20 HRSE024-A-20 HRSE012-A-20-T 45 Height 745 x Width 465 x Depth 620 HRSE018-A-20-T HRSE024-A-20-T HRSE012-A-23 41 Height 790 x Width 470