Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: B (w/Earth Leakage Breaker)
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Caster Adjuster-foot
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Fluid Fill Port, Manual Fill
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Earth Leakage Breaker
Specications Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Model HRS100-Al-20-l HRS150-Al-20-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.3 1.65 Control method PID control Ambient temperature Note 1) C 5 to 45 Circulating uid Note 2) Tap water, 15% ethylene glycol aqueous solution, Deionized water Set temperature range
Cooling Capacity: 150 (15.7kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 200 (20.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 100 (11.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: AK (w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill)
Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill
Cooling Capacity: 15.7kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 20.5kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 25kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
Cooling Capacity: 11.5kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: A + K
-A-20/40HRSH150-W-20/4025 25 Facility water temperature 32C Ambient temperature 32C 20 20 Cooling capacity [kW] Cooling capacity [kW] 15.7 15.7 15 15 Ambient temperature 43C 10 10 Facility water temperature 40C Ambient temperature 45C 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH200-A-20/40HRSH200-W-20/4030 30 Ambient
25C Ambient temperature 2C 0.5 0.5 Ambient temperature 2C 0 0 15 20 25 Circulating fluid temperature [C] 15 20 25 Circulating fluid temperature [C] HRLE050-W-20 HRLE050-W-20 [50 Hz] [60 Hz] 2 2 Heating capacity [kW] Heating capacity [kW] 1.5 1.5 Facility water temperature 25C, 32C, 40C Facility water temperature 25C, 32C, 40C 1 1 0.5 0.5 0 0 15 20 25 Circulating fluid temperature [C] 15
-Am-20 (CH1) HRL100-Am-20 (CH1) 0.6 0.6 60 60 0.5 0.5 50 50 Circulating fluid outlet Circulating fluid outlet 0.4 0.4 40 40 Usable flow rate range Usable flow rate range 0.3 0.3 30 30 0.2 0.2 20 20 Circulating fluid return port 0.1 0.1 10 10 Circulating fluid return port 0 0 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Pump Circulating fluid Pump