Applicable model HRS-WL003 HRS090-mm-20/40 Parts List q No.
Filter Rc3/8 20 m V V 5 Flow meter Rc1 V Prepare a flow meter with an appropriate flow range.
Applicable model Rated current [A] Sensitivity of leak current [mA] Short circuit display method HRSH100--20-B 30 Earth leakage breaker HRSH150--20-B HRSH200--20-B 40 HRSH250--20-B 50 HRSH300--20-B 30 Mechanical button * 400 V type is equipped as standard.
HRS 100/150 HRS 100/150 Applicable model Dimension [mm] A B C HRS100/150-A-20/40-A 830 302 1552 HRS100/150-W-20/40-A 570 401 1353 C HRSH 090 HRSH 118 HRSE A B Option symbol With Earth Leakage Breaker B HRZ HRZD HRS 20 B With earth leakage breaker HRW A leakage breaker is built in to automatically stop the supply power when it has short-circuit, over current or electrical leakage.
HED Polypropylene skid HEA Model Weight [kg] Dimensions [mm] HRSE012-A-10 35 Height 745 x Width 465 x Depth 575 HRSE018-A-10 HRSE012-A-10-T 42 Height 745 x Width 465 x Depth 620 HRSE018-A-10-T HRSE012-A-20 38 Height 745 x Width 465 x Depth 575 HRSE018-A-20 HRSE024-A-20 HRSE012-A-20-T 45 Height 745 x Width 465 x Depth 620 HRSE018-A-20-T HRSE024-A-20-T HRSE012-A-23 41 Height 790 x Width 470
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: -
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J (w/Automatic Fluid Fill Function)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: W (SI Unit Only)
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J + M
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: w/Automatic Fluid Fill Function
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: SI Unit Only
HRS090, CHILLER, 729, 1 lb
-A-20, CHILLER, 30.00000 lb
-A-20, CHILLER, 729, 110 lb
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]