SMC Corporation of America
Elite Part Number Search
Search Results "HRS024-AN-20-JM"

North American type Made to Order Basic type Bore size (inch-Nominal) Stroke/Hundredths of an inch 6 1/4" Stroke/Inch 10 3/8" 15 5/8" 20 3/4" 25 1" 32 1-1/4" 40 1-1/2" 50 2" 63 2-1/2" Standard Stroke Bore size Standard stroke (inch) Max. stroke (inch) (mm) (inch-Nominal) 2, 3, 4, 5, 6, 8, 10 2, 3, 4, 5, 6, 8, 10 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5,

Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: JM (J + M)

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: JM (J + M)

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: J + M

Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: J + M

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, BASE FOR HRS024-AN-20-JMT-X021, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING,

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, MAIN PC BOARD / HRS024-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, MAIN PC BOARD / HRS024-A-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, MAIN PC BOARD / HRS024-A-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING,

Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None

Applicable bore size (mm) C B1 d H1 JM-025-SUS 20 12.4 11.0 1/4 -28 4.0 JM-03-SUS 25 14.2 12.6 5/16 -24 4.8 JM-045-SUS 32, 40 19.6 17.3 7/16 -20 6.4 JM-05-SUS 50, 63 21.4 18.8 1/2 -20 7.9 JM-08-SUS 80 27.4 23.9 5/8 -18 9.7 JM-10-SUS 100 33 28.7 3/4-16 10.7 14 Series CJ5-S/CG5-S Auto Switch Specifications Auto Switch Common Specifications Lead Wire Length The standard lead wire length for

mA NCD-J016 16 D-C76 Grommet PLC 4 ~ 8 VDC 20 mA Double Rod Clevis NY-J010B 10 24V AC/DC or less 50mA NY-J016B 16 D-C80 Grommet PLC 48V AC/DC 40mA Rod Jam Nut JM-005 8 100V AC/DC 20mA JM-006 10 D-C73C Connector PLC 24 VDC 5 ~ 40 mA JM-02 16 D-C80C Connector PLC 24V AC/DC 50 mA Mounting Nut JM-025 8 or less JM-03 10 D-H7A1 Grommet PLC 28 VDC 40 mA JM-04 16 D-H7A2 Grommet PLC 28 VDC 80 mA