Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: MT (M + T)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: T (High-pressure Pump)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJMT (B + J + M + T)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JT (J + T)
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Automatic Water Supply Function
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + M
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: M + T
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: High-pressure Pump
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + J + M + T
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Earth Leakage Breaker
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + T
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge temp. 4 High circulating fluid return temp. 5 High circulating
(In such a case, use a bypass piping set (sold separately).) 8 Purchase an earth leakage breaker with current sensitivity of 30 mA separately. 9 Front: 1 m, height: 1 m, stable with no load, Other conditions See 3. 10 Weight in the dry state without circulating uids 9
Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-W-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb