10-32 UNF 10-32 UNF 1/4-20 UNC NT 1/4-20 1/4-20 5/16-18 TN 0.62 0.81 1.12 WF 0.34 0.47 0.38 YE 0.88 1.22 1.57 XA 0.38 0.62 0.88 Bore size (inch) 075 (3/4") 106 (1-1/16") 150 (1-1/2") 0 0.002 0 0.002 0 0.002 Block Mount ZB Bore size (inch) No bumper 3.22 3.75 4.19 With bumper 3.22 3.88 4.32 075 (3/4") 106 (1-1/16") 150 (1-1/2") Note) Length not affected by addition of magnet. 10 Series NCM
screw tap NT-UNC Data (in) Bore size (in) MM KK NT XA NH YE WF TN NE EA EE DD A AA B CA D E NA 075 (3/4") 10-32 UNF 0.625 0.75 1.12 0.38 0.88 0.34 0.62 0.81 0.12 1.00 1/8 1.00 0.093 0.22 1/4-28 10-32 UNF 1/4-20 0.250 106 (1 1/16") 10-32 UNF 0.750 0.75 1.47 0.62 1.22 0.47 0.81 0.24 1.12 1.25 1/8 1.25 0.093 0.25 3/16-24 10-32 UNF 1/4-20 0.312 150 (1 1/2") 1/4-20 NUC 1.00 1.25 1.93 0.88 1.57
double shaft length Change of double shaft length XA38 K 10, 15, 20, 30, 40 MSZ K J XA39 XA40 XA41 XA45 K K K XA46 CRQ2X MSQX Y Y Y Y Y 20, 30, 40 Y MRQ K, T J K K, T K 10, 15, 20, 30, 40 K K K K, T K X Z X, Z J Z J J, Z J 20, 30, 40 Z J 10, 15, 20, 30, 40 J T Reversed shaft, Change of double shaft length X 20, 30, 40 Reversed shaft, Change of double shaft
Change of double shaft length Change of double shaft length XA38 K 10, 15, 20, 30, 40 MRQ K J XA39 XA40 XA41 XA45 K K K XA46 Y Y Y Y Y 20, 30, 40 Y J K K, T K, T K 10, 15, 20, 30, 40 K K K K, T K Z X X, Z J J J, Z Z J 20, 30, 40 Z J 10, 15, 20, 30, 40 T J Reversed shaft, Change of double shaft length X 20, 30, 40 Reversed shaft, Change of double shaft length Combination
CY1S15, 20 to 40 (mm) J x K GP G FB A L B C D d EA EB FA H HA HG HP HT HS HB Model CY1S15 CDY1S15 CY1S20 CDY1S20 CY1S25 CDY1S25 CY1S32 CDY1S32 CY1S40 CDY1S40 7.5 9.5 5 16.6 12 6 13 3 40 29 13 39 21 15 1 52 6.5 6 60 M6 x 1.0 x 9.5 10 9.5 5.2 21.6 16 46 36 17 45 20 25.5 4.5 62 8.5 70 M6 x 1.0 x 9.5 10 11 6.5 26.4 16 8 14 4 54 40 20 53 20 23 9 70 8.5 7 70 M8 x 1.25 x 10 12.5 14 8 33.6 20 8
drawing shows HRS090-W-20.)
25 REAH15, 20, 25 REAH15, 20, 25 REAH15, 20 REAH15, 20 REAH25 REAH15, 20 REAH25 High Precision Guide Type REAH 0.08 Deflection (mm) Deflection (mm) Deflection (mm) Deflection (mm) 0.03 REAH25 0.02 0.06 0.02 0.04 0.01 0.01 0.02 Max.
HRSH090 A 20 Option Cooling capacity None Nill 090 9.5kW Earth leakage breaker B1 DI water (pure water) piping M Cooling method Automatic water-fill J A Air-cooled refrigeration CE / UL S Fixed SI unit W W Water-cooled refrigeration 1: In case of power supply '40' and option S, this is standard. 2: Power supply '20' only. *3: Unit : MPa/ degree Celsius) Piping thread type Power supply 20
(mm) Bore size (mm) WA WB WH W ZZ 20 22 16 23 30 118 25 22 16 25 30 123 32 22 16 28.5 25 125 40 22 16 33 20 143 50 25 18 40.5 20 167 63 25 18 47.5 20 167 80 30 22 60.5 20 201 100 31 22 71 20 202 10 Series CG5-S Dimensions R V Axial foot type (L)/CG5LNS S + Stroke H GA GB Width across flats B1 2P H1 D B LH I AL A K KA MM Width across flats NA LT M X Y X Y 8-J 4-LD C 0.1 LS + Stroke LX LZ ZZ
7 t CY3R15, 20 CY3R15 Parts list No. Description No.
7 t CY3R15, 20 CY3R15 Parts list No. Description No.
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
SY5000222-1A [for 10 valves (20 pcs.)] SY7000221-1A [for 10 valves (30 pcs.)] SY3000222-1A [for 10 valves (20 pcs.)] SY5000221-1A [for 10 valves (20 pcs.)] SY300023-24A [for 10 valves (20 pcs.)]
for stable operation (s/90) Allowable kinetic energy (J) Size 10 20 30 50 0.007 0.025 0.2 to 1.0 0.048 0.081 Note) If operated where the kinetic energy exceeds the allowable value, this may cause damage to the internal parts and result in product failure.
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Cooling Capacity: Cooling Capacity: 1700/1900W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: -
[mm] Bore size Stroke range A B CD CT CU CW CX CY CZ D E J K L M XC26A XC26B XC26C 32 125, 150, 175, 200, 250, 300 143.5 45.5 10 5 14 20 12.5 52.5 36 16 45 4.5 14 56 34 40 155 55 10 6 14 22 16.5 19.5 12.5 52.5 36 16 52 5 14 56 40 50 182.5 55.5 14 7 20 28 16.5 19.5 12.5 66 44 20 64 7 17 69 50 63 186 57 14 8 20 30 16.5 19.5 12.5 66 44 20 77 7 17 69 60 Bore size O P Q R RR RR1 Th9 U1 W Z A1
$2 are for 20 to 40.
52 : 1 3/4-12 85 : M24 x 1.5 25 : 5/8-11 53 : 1 3/4-5 86 : M26 x 1.5 26 : 5/8-18 54 :1 7/8-12 87 : M30 x 1.5 FEMALE ROD DIAMETER BORE (INCH) A B C MM KK WF 150 (1.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 200 (2) 3/4 1 1/8 3/8 5/8 7/16-20 1 250 (2.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 325 (3.25) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 400 (4) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 22 Air Cylinder Extended Series NCA1 PARTS
52 : 1 3/4-12 85 : M24 x 1.5 25 : 5/8-11 53 : 1 3/4-5 86 : M26 x 1.5 26 : 5/8-18 54 :1 7/8-12 87 : M30 x 1.5 FEMALE ROD DIAMETER BORE (INCH) A B C MM KK WF 150 (1.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 200 (2) 3/4 1 1/8 3/8 5/8 7/16-20 1 250 (2.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 325 (3.25) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 400 (4) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 22 Air Cylinder Extended Series NCA1 PARTS