SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-W-20"

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

-A-0 HRS024-A-20 . 9-7 9.3.2 HRS012-W-0 HRS018-W-0 HRS024-W-20 . 9-7 9.4 Cooling capacity . 9-8 9.4.1 HRS012--10-(BJMT) . 9-8 9.4.2 HRS018--10-(BJMT) . 9-8 9.4.3 HRS012--20-(BJMT) . 9-9 9.4.4 HRS018--20-(BJMT) . 9-9 9.4.5 HRS024--20-(BJMT) . 9-9 9.4.6 Option G [High temperature type] . 9-10 9.5 Heating capacity . 9-11 HRS Series HRX-OM-M090 Contents 9.5.1 HRS012--10,HRS018--10 . 9-11 9.5.2

) Note 20) Note 20) Note 20) Note 20) Note 20) Note 20) Note 15) The combination of metal bowl: 2 and 8 is not available.

/030-A-20-R . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS018-A-20--R . 9-7 9.4.2 HRS030-A-20--R . 9-7 9.5 Heating capacity . 9-8 9.5.1 HRS018-A-20-R, HRS030-A-20-R . 9-8 9.6 Pump capacity. 9-9 9.6.1 HRS018-A-20-R, HRS030-A-20-R . 9-9 9.6.2 HRS018-A-20-T-R, HRS030-A-20-T-R . 9-9 9.7 Compliance . 9-10 9.8 Sample DoC. . 9-11 9.9 Daily Check Sheet . 9-12 Chapter 10 Product Warranty . 10-1 HRS-R

Thermo-chiller Single-phase 200 to 230 VAC Environmentally Resistant Type HRS-R Series How to Order 018 A R 20 HRS Air-cooled refrigeration Stainless steel panel specication (Option) Cooling capacity 018 Cooling capacity 1700/1900 W (50/60 Hz) 030 Cooling capacity 2500/2900 W (50/60 Hz) Environmentally resistant type R Environmentally resistant type Cooling method Option A Air-cooled refrigeration

HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating

Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-W-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)